Fire resistance of ECC materials

A fire attack is one of the most severe conditions that a structure can be subjected to. Its consequence is not limited to damages on structural components but also on the livelihood of people use the facility. Engineered cementitious composites (ECC) are a relatively new concrete material that inco...

Full description

Saved in:
Bibliographic Details
Main Author: Toh, Elaine Siock Hui
Other Authors: Tan Kang Hai
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/64450
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-64450
record_format dspace
spelling sg-ntu-dr.10356-644502023-03-03T17:10:32Z Fire resistance of ECC materials Toh, Elaine Siock Hui Tan Kang Hai School of Civil and Environmental Engineering DRNTU::Engineering::Civil engineering A fire attack is one of the most severe conditions that a structure can be subjected to. Its consequence is not limited to damages on structural components but also on the livelihood of people use the facility. Engineered cementitious composites (ECC) are a relatively new concrete material that incorporates fibres in the mix design. It is considered a more environmentally friendly substitute to normal concrete because of the partial replacement of cement content with waste materials such as fly ash. One of its characteristics is the high ductility, which is the reason behind the name 'bendable concrete'. In terms of sustainability, this type of concrete is likely to have a potential market in the future due to its many beneficial characteristics. However, there are limited researches in the area of fire resistance of ECC. In this study, an experimental programme had been set up to study the effects of design parameters, such as water/binder ratio; fly ash (FA) replacement ratio, sand/binder ratio, addition of steel fibres to polyvinyl alcohol(PVA) fibre - ECC; ground-granulated blast-furnace slag (GGBS) and FA replacement ratio. These parameters were studied as the available materials in the laboratory were not similar, in terms of material properties, as compared to research papers. In addition, a new set up for direct tension test was devised to reduce the limitations of the existing set up. In total there were 9 mixes used to evaluate on the above stated parameters on the performance of ECC. After which, one mix that exhibited relatively well tensile stress and strain was chosen to be used for conducting of fire tests. 4 types of fire tests were carried out to determine the effect of fire on the local PVA-ECC. They are 3-hour spalling test, 2-hour spalling test, hot strength test and cold strength test. It was found that the mix with the lowest w/b ratio exhibited better tensile stress-strain relationship and therefore it was chosen for the fire test. After conducting the spalling tests for the local PVA-ECC, there was no observable spalling or cracks. It was deduced that PVA fibre might have helped in relieving the pressure and stress within the concrete by creating channels for these pressures to escape. In the hot strength test, 74.6% residual strength was obtained and even after the compressive strength test, the cylinder specimen remained intact. It was concluded that ECC exhibits potential fire resistance characteristics but more researches should still be conducted to ensure the consistency in results. Bachelor of Engineering (Civil) 2015-05-27T01:46:35Z 2015-05-27T01:46:35Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/64450 en Nanyang Technological University 65 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Civil engineering
spellingShingle DRNTU::Engineering::Civil engineering
Toh, Elaine Siock Hui
Fire resistance of ECC materials
description A fire attack is one of the most severe conditions that a structure can be subjected to. Its consequence is not limited to damages on structural components but also on the livelihood of people use the facility. Engineered cementitious composites (ECC) are a relatively new concrete material that incorporates fibres in the mix design. It is considered a more environmentally friendly substitute to normal concrete because of the partial replacement of cement content with waste materials such as fly ash. One of its characteristics is the high ductility, which is the reason behind the name 'bendable concrete'. In terms of sustainability, this type of concrete is likely to have a potential market in the future due to its many beneficial characteristics. However, there are limited researches in the area of fire resistance of ECC. In this study, an experimental programme had been set up to study the effects of design parameters, such as water/binder ratio; fly ash (FA) replacement ratio, sand/binder ratio, addition of steel fibres to polyvinyl alcohol(PVA) fibre - ECC; ground-granulated blast-furnace slag (GGBS) and FA replacement ratio. These parameters were studied as the available materials in the laboratory were not similar, in terms of material properties, as compared to research papers. In addition, a new set up for direct tension test was devised to reduce the limitations of the existing set up. In total there were 9 mixes used to evaluate on the above stated parameters on the performance of ECC. After which, one mix that exhibited relatively well tensile stress and strain was chosen to be used for conducting of fire tests. 4 types of fire tests were carried out to determine the effect of fire on the local PVA-ECC. They are 3-hour spalling test, 2-hour spalling test, hot strength test and cold strength test. It was found that the mix with the lowest w/b ratio exhibited better tensile stress-strain relationship and therefore it was chosen for the fire test. After conducting the spalling tests for the local PVA-ECC, there was no observable spalling or cracks. It was deduced that PVA fibre might have helped in relieving the pressure and stress within the concrete by creating channels for these pressures to escape. In the hot strength test, 74.6% residual strength was obtained and even after the compressive strength test, the cylinder specimen remained intact. It was concluded that ECC exhibits potential fire resistance characteristics but more researches should still be conducted to ensure the consistency in results.
author2 Tan Kang Hai
author_facet Tan Kang Hai
Toh, Elaine Siock Hui
format Final Year Project
author Toh, Elaine Siock Hui
author_sort Toh, Elaine Siock Hui
title Fire resistance of ECC materials
title_short Fire resistance of ECC materials
title_full Fire resistance of ECC materials
title_fullStr Fire resistance of ECC materials
title_full_unstemmed Fire resistance of ECC materials
title_sort fire resistance of ecc materials
publishDate 2015
url http://hdl.handle.net/10356/64450
_version_ 1759856621141360640