Measurement of a 5:1 blood pump model

Mechanical Circulatory System was developed to provide cardiovascular disease patients with heart transplant alternative. The Kyoto University Magnetically Suspended Centrifugal Blood Pump uses magnetically suspended impeller to eliminate the use of bearing and seal, thus reducing heat generation, l...

Full description

Saved in:
Bibliographic Details
Main Author: Soh, Boon Chuan
Other Authors: Chua Leok Poh
Format: Final Year Project
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/67776
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-67776
record_format dspace
spelling sg-ntu-dr.10356-677762023-03-04T18:36:57Z Measurement of a 5:1 blood pump model Soh, Boon Chuan Chua Leok Poh School of Mechanical and Aerospace Engineering DRNTU::Engineering Mechanical Circulatory System was developed to provide cardiovascular disease patients with heart transplant alternative. The Kyoto University Magnetically Suspended Centrifugal Blood Pump uses magnetically suspended impeller to eliminate the use of bearing and seal, thus reducing heat generation, leakage and contamination of blood. However, hemolysis and thrombus formation in the 0.2 mm clearance gap between the impeller surface and the pump casing is of primary concern. An enlarged model using of five times was built by applying dimensional analysis and the pump similarity law to study the fluid flow behavior within the clearance gap. Hot wire anemometry was used to measure the tangential and radial velocity at 3 axial planes (z/d = 0.25, 0.5 and 0.75). A total of 504 readings (7 radial x 72 angular) were taken at each axial plane. The tangential, radial, resultant, flow angle and vector plots were presented in this report. The results obtained show flow magnitude is higher and flow in a more tangentially manner at the outer radial position and at the higher axial position. No recirculation was observed and washout effect was more dominant in the region near the splitter plate. These suggest that hemolysis and thrombus formations are minimal hence the pump is a compactable bio-centrifugal blood pump. The experimental data would be useful for future analysis and in developing an optimum blood pump design. Bachelor of Engineering (Mechanical Engineering) 2016-05-20T06:17:08Z 2016-05-20T06:17:08Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/67776 en Nanyang Technological University 65 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Soh, Boon Chuan
Measurement of a 5:1 blood pump model
description Mechanical Circulatory System was developed to provide cardiovascular disease patients with heart transplant alternative. The Kyoto University Magnetically Suspended Centrifugal Blood Pump uses magnetically suspended impeller to eliminate the use of bearing and seal, thus reducing heat generation, leakage and contamination of blood. However, hemolysis and thrombus formation in the 0.2 mm clearance gap between the impeller surface and the pump casing is of primary concern. An enlarged model using of five times was built by applying dimensional analysis and the pump similarity law to study the fluid flow behavior within the clearance gap. Hot wire anemometry was used to measure the tangential and radial velocity at 3 axial planes (z/d = 0.25, 0.5 and 0.75). A total of 504 readings (7 radial x 72 angular) were taken at each axial plane. The tangential, radial, resultant, flow angle and vector plots were presented in this report. The results obtained show flow magnitude is higher and flow in a more tangentially manner at the outer radial position and at the higher axial position. No recirculation was observed and washout effect was more dominant in the region near the splitter plate. These suggest that hemolysis and thrombus formations are minimal hence the pump is a compactable bio-centrifugal blood pump. The experimental data would be useful for future analysis and in developing an optimum blood pump design.
author2 Chua Leok Poh
author_facet Chua Leok Poh
Soh, Boon Chuan
format Final Year Project
author Soh, Boon Chuan
author_sort Soh, Boon Chuan
title Measurement of a 5:1 blood pump model
title_short Measurement of a 5:1 blood pump model
title_full Measurement of a 5:1 blood pump model
title_fullStr Measurement of a 5:1 blood pump model
title_full_unstemmed Measurement of a 5:1 blood pump model
title_sort measurement of a 5:1 blood pump model
publishDate 2016
url http://hdl.handle.net/10356/67776
_version_ 1759853425159307264