Thermal imaging of a vein in the forearm: any correlation to blood pressure?

Blood pressure is one of the most important measurements for the human health. The main reason for the need to monitor blood pressure regularly is to prevent cardiovascular diseases. Currently, the most common equipment used to measuring blood pressure is a sphygmomanometer. This measurement tool w...

Full description

Saved in:
Bibliographic Details
Main Author: Tan, Wei Long
Other Authors: Ng Yin Kwee
Format: Final Year Project
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/67791
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-67791
record_format dspace
spelling sg-ntu-dr.10356-677912023-03-04T19:19:47Z Thermal imaging of a vein in the forearm: any correlation to blood pressure? Tan, Wei Long Ng Yin Kwee School of Mechanical and Aerospace Engineering DRNTU::Engineering Blood pressure is one of the most important measurements for the human health. The main reason for the need to monitor blood pressure regularly is to prevent cardiovascular diseases. Currently, the most common equipment used to measuring blood pressure is a sphygmomanometer. This measurement tool will provide the values of the systolic and diastolic pressures of the human body. However, this method causes much discomfort to the person measuring his/her blood pressure due to expanding of the cuffs. Previous researchers have tried to use the technique of thermal imaging and processing to study blood flow and pressure. This technique would be possible, however, the cost of equipment (thermal camera and processer) is far too expensive. This project was carried out in hopes to find a non-invasive method of measuring superficial temperature using a contactless thermal sensing thermometer and thermocouples, correlating temperature with blood velocity. Finally to obtain blood pressure readings from correlating to blood velocity. In order to achieve this objective, previous methods of using thermal imaging were studied in order to look for similarities. A mathematical model was derived based on previous work by previous researchers. Then after, simulations were carried out using COMSOL Multiphysics with a simplified model of the human forearm. Experiments were carried out to firstly verify the results of the simulations of superficial skin temperature. Further experiments were done with the aim of obtaining fluid velocity and pressure by using correlations of superficial temperature. Bachelor of Engineering (Mechanical Engineering) 2016-05-20T08:06:14Z 2016-05-20T08:06:14Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/67791 en Nanyang Technological University 96 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Tan, Wei Long
Thermal imaging of a vein in the forearm: any correlation to blood pressure?
description Blood pressure is one of the most important measurements for the human health. The main reason for the need to monitor blood pressure regularly is to prevent cardiovascular diseases. Currently, the most common equipment used to measuring blood pressure is a sphygmomanometer. This measurement tool will provide the values of the systolic and diastolic pressures of the human body. However, this method causes much discomfort to the person measuring his/her blood pressure due to expanding of the cuffs. Previous researchers have tried to use the technique of thermal imaging and processing to study blood flow and pressure. This technique would be possible, however, the cost of equipment (thermal camera and processer) is far too expensive. This project was carried out in hopes to find a non-invasive method of measuring superficial temperature using a contactless thermal sensing thermometer and thermocouples, correlating temperature with blood velocity. Finally to obtain blood pressure readings from correlating to blood velocity. In order to achieve this objective, previous methods of using thermal imaging were studied in order to look for similarities. A mathematical model was derived based on previous work by previous researchers. Then after, simulations were carried out using COMSOL Multiphysics with a simplified model of the human forearm. Experiments were carried out to firstly verify the results of the simulations of superficial skin temperature. Further experiments were done with the aim of obtaining fluid velocity and pressure by using correlations of superficial temperature.
author2 Ng Yin Kwee
author_facet Ng Yin Kwee
Tan, Wei Long
format Final Year Project
author Tan, Wei Long
author_sort Tan, Wei Long
title Thermal imaging of a vein in the forearm: any correlation to blood pressure?
title_short Thermal imaging of a vein in the forearm: any correlation to blood pressure?
title_full Thermal imaging of a vein in the forearm: any correlation to blood pressure?
title_fullStr Thermal imaging of a vein in the forearm: any correlation to blood pressure?
title_full_unstemmed Thermal imaging of a vein in the forearm: any correlation to blood pressure?
title_sort thermal imaging of a vein in the forearm: any correlation to blood pressure?
publishDate 2016
url http://hdl.handle.net/10356/67791
_version_ 1759854177519927296