Miniaturized microvalve for microfluidics application
Advances in the field of microfluidics have led to the widespread adoption of microfluidic devices used in a wide range of applications including clinical diagnosis and biochemical research. A main advantage of microfluidic devices such as Micro Total Analysis Systems (μTAS) is that they allow for p...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2016
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/67833 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-67833 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-678332023-03-04T18:23:06Z Miniaturized microvalve for microfluidics application Lee, Sheung Jien Li King Ho Holden School of Mechanical and Aerospace Engineering A*STAR Singapore Institute of Manufacturing Technology DRNTU::Engineering Advances in the field of microfluidics have led to the widespread adoption of microfluidic devices used in a wide range of applications including clinical diagnosis and biochemical research. A main advantage of microfluidic devices such as Micro Total Analysis Systems (μTAS) is that they allow for point-of-care or on-site use, thus significantly reducing analysis times and operating costs. These microfluidic platforms require microfluidic components such as microvalves, which need to be small and easily integrated into existing platforms. This project involves the design, fabrication and characterization of a miniaturized active multi-way microvalve. The microvalve is designed for integration into microfluidic chips and is small in size, reducing the overall size of microfluidic platforms. The microvalve uses a rotary mechanism with a specially designed compressible rotor made of Viton© elastomer to both provide a seal and switch between outlets precisely, with other components made of machined polymethyl methacrylate (PMMA). The microvalve is actuated manually but can be modified to accept automatic actuation using a suitable small stepper motor. The small size, simple design and relative ease of fabrication makes the microvalve presented in this project viable for use in disposable or single-use microfluidic chips which are to be mass manufactured. The miniaturized rotary microvalve presented here in this project is able to withstand pressures up to 370kPa with no leakage and has a switching torque of under 0.03Nm. Bachelor of Engineering (Mechanical Engineering) 2016-05-21T06:56:29Z 2016-05-21T06:56:29Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/67833 en Nanyang Technological University 64 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering |
spellingShingle |
DRNTU::Engineering Lee, Sheung Jien Miniaturized microvalve for microfluidics application |
description |
Advances in the field of microfluidics have led to the widespread adoption of microfluidic devices used in a wide range of applications including clinical diagnosis and biochemical research. A main advantage of microfluidic devices such as Micro Total Analysis Systems (μTAS) is that they allow for point-of-care or on-site use, thus significantly reducing analysis times and operating costs. These microfluidic platforms require microfluidic components such as microvalves, which need to be small and easily integrated into existing platforms.
This project involves the design, fabrication and characterization of a miniaturized active multi-way microvalve. The microvalve is designed for integration into microfluidic chips and is small in size, reducing the overall size of microfluidic platforms. The microvalve uses a rotary mechanism with a specially designed compressible rotor made of Viton© elastomer to both provide a seal and switch between outlets precisely, with other components made of machined polymethyl methacrylate (PMMA). The microvalve is actuated manually but can be modified to accept automatic actuation using a suitable small stepper motor. The small size, simple design and relative ease of fabrication makes the microvalve presented in this project viable for use in disposable or single-use microfluidic chips which are to be mass manufactured.
The miniaturized rotary microvalve presented here in this project is able to withstand pressures up to 370kPa with no leakage and has a switching torque of under 0.03Nm. |
author2 |
Li King Ho Holden |
author_facet |
Li King Ho Holden Lee, Sheung Jien |
format |
Final Year Project |
author |
Lee, Sheung Jien |
author_sort |
Lee, Sheung Jien |
title |
Miniaturized microvalve for microfluidics application |
title_short |
Miniaturized microvalve for microfluidics application |
title_full |
Miniaturized microvalve for microfluidics application |
title_fullStr |
Miniaturized microvalve for microfluidics application |
title_full_unstemmed |
Miniaturized microvalve for microfluidics application |
title_sort |
miniaturized microvalve for microfluidics application |
publishDate |
2016 |
url |
http://hdl.handle.net/10356/67833 |
_version_ |
1759853886551621632 |