Miniaturized microvalve for microfluidics application

Advances in the field of microfluidics have led to the widespread adoption of microfluidic devices used in a wide range of applications including clinical diagnosis and biochemical research. A main advantage of microfluidic devices such as Micro Total Analysis Systems (μTAS) is that they allow for p...

Full description

Saved in:
Bibliographic Details
Main Author: Lee, Sheung Jien
Other Authors: Li King Ho Holden
Format: Final Year Project
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/67833
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-67833
record_format dspace
spelling sg-ntu-dr.10356-678332023-03-04T18:23:06Z Miniaturized microvalve for microfluidics application Lee, Sheung Jien Li King Ho Holden School of Mechanical and Aerospace Engineering A*STAR Singapore Institute of Manufacturing Technology DRNTU::Engineering Advances in the field of microfluidics have led to the widespread adoption of microfluidic devices used in a wide range of applications including clinical diagnosis and biochemical research. A main advantage of microfluidic devices such as Micro Total Analysis Systems (μTAS) is that they allow for point-of-care or on-site use, thus significantly reducing analysis times and operating costs. These microfluidic platforms require microfluidic components such as microvalves, which need to be small and easily integrated into existing platforms. This project involves the design, fabrication and characterization of a miniaturized active multi-way microvalve. The microvalve is designed for integration into microfluidic chips and is small in size, reducing the overall size of microfluidic platforms. The microvalve uses a rotary mechanism with a specially designed compressible rotor made of Viton© elastomer to both provide a seal and switch between outlets precisely, with other components made of machined polymethyl methacrylate (PMMA). The microvalve is actuated manually but can be modified to accept automatic actuation using a suitable small stepper motor. The small size, simple design and relative ease of fabrication makes the microvalve presented in this project viable for use in disposable or single-use microfluidic chips which are to be mass manufactured. The miniaturized rotary microvalve presented here in this project is able to withstand pressures up to 370kPa with no leakage and has a switching torque of under 0.03Nm. Bachelor of Engineering (Mechanical Engineering) 2016-05-21T06:56:29Z 2016-05-21T06:56:29Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/67833 en Nanyang Technological University 64 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Lee, Sheung Jien
Miniaturized microvalve for microfluidics application
description Advances in the field of microfluidics have led to the widespread adoption of microfluidic devices used in a wide range of applications including clinical diagnosis and biochemical research. A main advantage of microfluidic devices such as Micro Total Analysis Systems (μTAS) is that they allow for point-of-care or on-site use, thus significantly reducing analysis times and operating costs. These microfluidic platforms require microfluidic components such as microvalves, which need to be small and easily integrated into existing platforms. This project involves the design, fabrication and characterization of a miniaturized active multi-way microvalve. The microvalve is designed for integration into microfluidic chips and is small in size, reducing the overall size of microfluidic platforms. The microvalve uses a rotary mechanism with a specially designed compressible rotor made of Viton© elastomer to both provide a seal and switch between outlets precisely, with other components made of machined polymethyl methacrylate (PMMA). The microvalve is actuated manually but can be modified to accept automatic actuation using a suitable small stepper motor. The small size, simple design and relative ease of fabrication makes the microvalve presented in this project viable for use in disposable or single-use microfluidic chips which are to be mass manufactured. The miniaturized rotary microvalve presented here in this project is able to withstand pressures up to 370kPa with no leakage and has a switching torque of under 0.03Nm.
author2 Li King Ho Holden
author_facet Li King Ho Holden
Lee, Sheung Jien
format Final Year Project
author Lee, Sheung Jien
author_sort Lee, Sheung Jien
title Miniaturized microvalve for microfluidics application
title_short Miniaturized microvalve for microfluidics application
title_full Miniaturized microvalve for microfluidics application
title_fullStr Miniaturized microvalve for microfluidics application
title_full_unstemmed Miniaturized microvalve for microfluidics application
title_sort miniaturized microvalve for microfluidics application
publishDate 2016
url http://hdl.handle.net/10356/67833
_version_ 1759853886551621632