Design of upper-arm module for a cable driven upper limb exoskeleton

Stroke rehabilitation is essential and very important to stroke survivors to provide them with opportunity to relearn skills that they have lost after stroke. Stroke patient would have to undergo regular sessions of rehabilitation by dedicated therapist to regain skills that are essential for them t...

Full description

Saved in:
Bibliographic Details
Main Author: Phang, Wei Jian
Other Authors: Low Kin Huat
Format: Final Year Project
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/67933
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-67933
record_format dspace
spelling sg-ntu-dr.10356-679332023-03-04T18:23:02Z Design of upper-arm module for a cable driven upper limb exoskeleton Phang, Wei Jian Low Kin Huat School of Mechanical and Aerospace Engineering Robotics Research Centre DRNTU::Engineering Stroke rehabilitation is essential and very important to stroke survivors to provide them with opportunity to relearn skills that they have lost after stroke. Stroke patient would have to undergo regular sessions of rehabilitation by dedicated therapist to regain skills that are essential for them to carry out daily task and these rehabilitation sessions may last up to years for the patient to fully recover depending on the severity of the patient’s condition. These rehabilitation are costly and also requires patient to travel to dedicated rehabilitation centre. For years, many researches and studies are done to provide alternate solution for stroke rehabilitation process, as such many studies are done in the field of incorporating robots into rehabilitation process in order to reduce cost and reduce hassle of patient to travel to a rehabilitation centre. In this study, we look into providing inexpensive and wearable upper limb rehabilitation exoskeleton that is lightweight and portable that can be carried around. The wearable upper limb exoskeleton is driven by cable system which is worn over the upper body with actuator system carried in a form of bag-pack by the user. This report presents initial designs of the system, fabrication and assembly of the system as well as evaluation of effectiveness of system through experimental testing and simulations to show that the system can be easily wearable, light weighted and able to function effectively as intended. The studies of initial design of this system will serve as initiatives for further development and improvement of cable driven wearable upper limb exoskeleton system. Bachelor of Engineering (Mechanical Engineering) 2016-05-23T07:35:45Z 2016-05-23T07:35:45Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/67933 en Nanyang Technological University 103 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Phang, Wei Jian
Design of upper-arm module for a cable driven upper limb exoskeleton
description Stroke rehabilitation is essential and very important to stroke survivors to provide them with opportunity to relearn skills that they have lost after stroke. Stroke patient would have to undergo regular sessions of rehabilitation by dedicated therapist to regain skills that are essential for them to carry out daily task and these rehabilitation sessions may last up to years for the patient to fully recover depending on the severity of the patient’s condition. These rehabilitation are costly and also requires patient to travel to dedicated rehabilitation centre. For years, many researches and studies are done to provide alternate solution for stroke rehabilitation process, as such many studies are done in the field of incorporating robots into rehabilitation process in order to reduce cost and reduce hassle of patient to travel to a rehabilitation centre. In this study, we look into providing inexpensive and wearable upper limb rehabilitation exoskeleton that is lightweight and portable that can be carried around. The wearable upper limb exoskeleton is driven by cable system which is worn over the upper body with actuator system carried in a form of bag-pack by the user. This report presents initial designs of the system, fabrication and assembly of the system as well as evaluation of effectiveness of system through experimental testing and simulations to show that the system can be easily wearable, light weighted and able to function effectively as intended. The studies of initial design of this system will serve as initiatives for further development and improvement of cable driven wearable upper limb exoskeleton system.
author2 Low Kin Huat
author_facet Low Kin Huat
Phang, Wei Jian
format Final Year Project
author Phang, Wei Jian
author_sort Phang, Wei Jian
title Design of upper-arm module for a cable driven upper limb exoskeleton
title_short Design of upper-arm module for a cable driven upper limb exoskeleton
title_full Design of upper-arm module for a cable driven upper limb exoskeleton
title_fullStr Design of upper-arm module for a cable driven upper limb exoskeleton
title_full_unstemmed Design of upper-arm module for a cable driven upper limb exoskeleton
title_sort design of upper-arm module for a cable driven upper limb exoskeleton
publishDate 2016
url http://hdl.handle.net/10356/67933
_version_ 1759857030121652224