Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis

The vascular occlusion by the thrombi is the main reason for ischemic stroke and deep vein thrombosis. High-intensity focused ultrasound (HIFU) and histotripsy or microtripsy pulses can effectively dissolve the blood clot with no use of thrombolytic agent and ultrasound contrast agent (microbubble)....

Full description

Saved in:
Bibliographic Details
Main Author: Yang, Wenjing
Other Authors: Zhou Yufeng
Format: Final Year Project
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/68519
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-68519
record_format dspace
spelling sg-ntu-dr.10356-685192023-03-04T18:25:13Z Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis Yang, Wenjing Zhou Yufeng School of Mechanical and Aerospace Engineering DRNTU::Engineering::Bioengineering The vascular occlusion by the thrombi is the main reason for ischemic stroke and deep vein thrombosis. High-intensity focused ultrasound (HIFU) and histotripsy or microtripsy pulses can effectively dissolve the blood clot with no use of thrombolytic agent and ultrasound contrast agent (microbubble). In this study, HIFU bursts at the same duty cycle (5%) but varied pulse repetition frequency (PRF) from 1 Hz to 1000 Hz were delivered to in vitro porcine blood clot for 30 s. Thrombolysis efficiency initially increases slightly with the PRF, 86.4±10.3%, 89.9±11.9, and 92.9±12.8% at PRF of 1 Hz, 10 Hz, and 100 Hz, respectively, without significant difference (p > 0.05), but then drops dramatically to 37.9±6.9% at PRF of 1000 Hz (p < 0.05). The particle size in the supernant of dissolution is 547.1±129.5 nm, which suggests the disruption of thrombi into subcellular level. Thrombi motion during HIFU exposure shows violent motion and significant curling at low PRF, rotation about its axis with occasional curling at medium PRF, and localized vibration at high PRF due to the generation of acoustic radiation force and streaming. Quantitative analysis of recorded motion shows the displacement decreases with the PRF of delivered bursts, from 3.9±1.5 mm at 1 Hz to 0.7±0.4 mm at 1000 Hz. In summary, the PRF of delivered HIFU bursts at the same output power has a significant effect on the thrombi motion, bubble cavitation activities, and subsequently thrombolysis efficiencies. Bachelor of Engineering 2016-05-26T07:20:50Z 2016-05-26T07:20:50Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/68519 en Nanyang Technological University 41 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Bioengineering
spellingShingle DRNTU::Engineering::Bioengineering
Yang, Wenjing
Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
description The vascular occlusion by the thrombi is the main reason for ischemic stroke and deep vein thrombosis. High-intensity focused ultrasound (HIFU) and histotripsy or microtripsy pulses can effectively dissolve the blood clot with no use of thrombolytic agent and ultrasound contrast agent (microbubble). In this study, HIFU bursts at the same duty cycle (5%) but varied pulse repetition frequency (PRF) from 1 Hz to 1000 Hz were delivered to in vitro porcine blood clot for 30 s. Thrombolysis efficiency initially increases slightly with the PRF, 86.4±10.3%, 89.9±11.9, and 92.9±12.8% at PRF of 1 Hz, 10 Hz, and 100 Hz, respectively, without significant difference (p > 0.05), but then drops dramatically to 37.9±6.9% at PRF of 1000 Hz (p < 0.05). The particle size in the supernant of dissolution is 547.1±129.5 nm, which suggests the disruption of thrombi into subcellular level. Thrombi motion during HIFU exposure shows violent motion and significant curling at low PRF, rotation about its axis with occasional curling at medium PRF, and localized vibration at high PRF due to the generation of acoustic radiation force and streaming. Quantitative analysis of recorded motion shows the displacement decreases with the PRF of delivered bursts, from 3.9±1.5 mm at 1 Hz to 0.7±0.4 mm at 1000 Hz. In summary, the PRF of delivered HIFU bursts at the same output power has a significant effect on the thrombi motion, bubble cavitation activities, and subsequently thrombolysis efficiencies.
author2 Zhou Yufeng
author_facet Zhou Yufeng
Yang, Wenjing
format Final Year Project
author Yang, Wenjing
author_sort Yang, Wenjing
title Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
title_short Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
title_full Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
title_fullStr Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
title_full_unstemmed Extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
title_sort extracorporeal ultrasound angioplasty - effect of pulse repetition frequency of high-intensity focused ultrasound on thrombolysis
publishDate 2016
url http://hdl.handle.net/10356/68519
_version_ 1759858182147014656