Microfluidics nucleic acid testing for point-of-care liver assessment

Liver assessment is currently one of the most important medical diagnostics. The inherent complexities of current gold standards of liver assessment such as histopathology and Liver Function Tests are generally incompatible with point-of-care testing (POCT). Hence, there is a real need for a truly...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Geok Soon
Other Authors: Wang Zhiping
Format: Theses and Dissertations
Language:English
Published: 2016
Subjects:
Online Access:https://hdl.handle.net/10356/68640
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-68640
record_format dspace
spelling sg-ntu-dr.10356-686402023-07-04T15:36:50Z Microfluidics nucleic acid testing for point-of-care liver assessment Lim, Geok Soon Wang Zhiping Chang Joseph Sylvester School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Microelectromechanical systems Liver assessment is currently one of the most important medical diagnostics. The inherent complexities of current gold standards of liver assessment such as histopathology and Liver Function Tests are generally incompatible with point-of-care testing (POCT). Hence, there is a real need for a truly practical Lab-on-a-Chip (LOC) system POCT liver assessment. The embodiment of such a system should feature rapid, full-automation, ease-of-use, and sample-in-answer-out diagnostic capabilities. To date, reported microfluidic devices for POCT liver assessment remain largely rudimentary as they embody semi-integrated, semi-quantitative and single gene detection capabilities. In this thesis, we propose the use of microfluidics Nucleic Acid Testing (NAT) to demonstrate the feasibility for a practical and clinically pertinent POCT liver assessment device. In our research, we propose and realize two different integrated LOC systems for multiplex gene expression studies in POCT hepatotoxicity assessment. For our first integrated LOC system, we propose and describe an LOC system (stationary PCR approach) which encompasses the entire NAT process for sample-in-answer-out capabilities. Our first integrated LOC system embodies the integration and semi-automation of a tissue sample preparation module, a polymeric chip-compatible thermal cycler for multiplex RT-PCR, and a real-time fully-quantitative fluorescent detection methodology. To evaluate the feasibility of our first integrated LOC system in POCT hepatotoxicity assessment, we select and validate two different liver-critical genes of interest (GOIs) – namely, alanine transaminase and aspartate transaminase, based on critical liver protein biomarkers used in Liver Function Tests. To validate our integrated LOC system, we perform a preclinical drug toxicity animal study via the administration of cyclophosphamide, and subsequent microfluidic gene expression analysis depicts up-regulations in the GOIs’ expression levels – consistent with results obtained from conventional methodology. For our second integrated LOC system, we propose and describe an LOC system (continuous-flow PCR approach) which features a small equipment footprint and embodies an easy-to-assemble fluorescent detection module. With a contact-based isothermal heating setup, a polymeric biochip embodying a segmented flow approach, and a fully-quantitative coordinate-based detection methodology, we describe a method for multiplex gene expression analysis on a continuous-flow PCR platform. We demonstrate the rapidness of our second LOC system using the same drug-treated mice tissue samples, and illustrate significant reductions in RT-qPCR completion, wherein the entire process can be completed in <20mins – 3.9-fold faster than a conventional thermal cycler and ~3.15-fold faster than our first integrated LOC system embodying the stationary PCR approach. In short, both of our integrated LOC systems are designed to be somewhat close to a practical POCT liver assessment device, and feature semi-automation, relative ease-of-use, and sample-in-answer-out capabilities for multiplex gene expression analysis. Collectively, the contributions from both of our integrated LOC systems are pertinent towards the realization of a truly practical POCT liver assessment device. DOCTOR OF PHILOSOPHY (EEE) 2016-05-30T04:58:18Z 2016-05-30T04:58:18Z 2016 Thesis Lim, G. S. (2016). Microfluidics nucleic acid testing for point-of-care liver assessment. Doctoral thesis, Nanyang Technological University, Singapore. https://hdl.handle.net/10356/68640 10.32657/10356/68640 en 164 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering::Microelectromechanical systems
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Microelectromechanical systems
Lim, Geok Soon
Microfluidics nucleic acid testing for point-of-care liver assessment
description Liver assessment is currently one of the most important medical diagnostics. The inherent complexities of current gold standards of liver assessment such as histopathology and Liver Function Tests are generally incompatible with point-of-care testing (POCT). Hence, there is a real need for a truly practical Lab-on-a-Chip (LOC) system POCT liver assessment. The embodiment of such a system should feature rapid, full-automation, ease-of-use, and sample-in-answer-out diagnostic capabilities. To date, reported microfluidic devices for POCT liver assessment remain largely rudimentary as they embody semi-integrated, semi-quantitative and single gene detection capabilities. In this thesis, we propose the use of microfluidics Nucleic Acid Testing (NAT) to demonstrate the feasibility for a practical and clinically pertinent POCT liver assessment device. In our research, we propose and realize two different integrated LOC systems for multiplex gene expression studies in POCT hepatotoxicity assessment. For our first integrated LOC system, we propose and describe an LOC system (stationary PCR approach) which encompasses the entire NAT process for sample-in-answer-out capabilities. Our first integrated LOC system embodies the integration and semi-automation of a tissue sample preparation module, a polymeric chip-compatible thermal cycler for multiplex RT-PCR, and a real-time fully-quantitative fluorescent detection methodology. To evaluate the feasibility of our first integrated LOC system in POCT hepatotoxicity assessment, we select and validate two different liver-critical genes of interest (GOIs) – namely, alanine transaminase and aspartate transaminase, based on critical liver protein biomarkers used in Liver Function Tests. To validate our integrated LOC system, we perform a preclinical drug toxicity animal study via the administration of cyclophosphamide, and subsequent microfluidic gene expression analysis depicts up-regulations in the GOIs’ expression levels – consistent with results obtained from conventional methodology. For our second integrated LOC system, we propose and describe an LOC system (continuous-flow PCR approach) which features a small equipment footprint and embodies an easy-to-assemble fluorescent detection module. With a contact-based isothermal heating setup, a polymeric biochip embodying a segmented flow approach, and a fully-quantitative coordinate-based detection methodology, we describe a method for multiplex gene expression analysis on a continuous-flow PCR platform. We demonstrate the rapidness of our second LOC system using the same drug-treated mice tissue samples, and illustrate significant reductions in RT-qPCR completion, wherein the entire process can be completed in <20mins – 3.9-fold faster than a conventional thermal cycler and ~3.15-fold faster than our first integrated LOC system embodying the stationary PCR approach. In short, both of our integrated LOC systems are designed to be somewhat close to a practical POCT liver assessment device, and feature semi-automation, relative ease-of-use, and sample-in-answer-out capabilities for multiplex gene expression analysis. Collectively, the contributions from both of our integrated LOC systems are pertinent towards the realization of a truly practical POCT liver assessment device.
author2 Wang Zhiping
author_facet Wang Zhiping
Lim, Geok Soon
format Theses and Dissertations
author Lim, Geok Soon
author_sort Lim, Geok Soon
title Microfluidics nucleic acid testing for point-of-care liver assessment
title_short Microfluidics nucleic acid testing for point-of-care liver assessment
title_full Microfluidics nucleic acid testing for point-of-care liver assessment
title_fullStr Microfluidics nucleic acid testing for point-of-care liver assessment
title_full_unstemmed Microfluidics nucleic acid testing for point-of-care liver assessment
title_sort microfluidics nucleic acid testing for point-of-care liver assessment
publishDate 2016
url https://hdl.handle.net/10356/68640
_version_ 1772828266465329152