With the growing concern of global warming, substantial efforts were made to improve energy efficiency and environmental friendliness of refrigeration systems. In 2014, a new type of expander-compressor unit called Cross Vane Expander-Compressor (CVEC) has been invented by Yap et al. [1]. A mathemat...

Full description

Saved in:
Bibliographic Details
Main Author: Chong, Yue Kin
Other Authors: Ooi Kim Tiow
Format: Final Year Project
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/68808
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-68808
record_format dspace
spelling sg-ntu-dr.10356-688082023-03-04T18:46:40Z Heat transfer study of novel cross vane expander-compressor unit Chong, Yue Kin Ooi Kim Tiow School of Mechanical and Aerospace Engineering DRNTU::Engineering With the growing concern of global warming, substantial efforts were made to improve energy efficiency and environmental friendliness of refrigeration systems. In 2014, a new type of expander-compressor unit called Cross Vane Expander-Compressor (CVEC) has been invented by Yap et al. [1]. A mathematical model that comprises of geometrical model, thermodynamics model and etc. is developed and simulated to study the working performance of CVEC. However, it is noticed that heat transfer is yet not taken into account of the mathematical model. In this project, a heat transfer model is developed and integrated into the mathematical model of CVEC to study the effect of heat transfer on CVEC performance. The theoretical simulation results shows that a specific suction valve angle of the expander fits only a particular operating condition. Failure to design the suction valve opening angle according to the operating condition would result in under or over-expansion of the expander discharge fluid. Some suggestions are then given to overcome this problem. Moreover, it is found out that the heat transfer rate increases significantly as the thermal conductivity of the expander-compressor unit increases but the COP is not greatly affected. This result suggests that the effects of heat transfer to the performance of CVEC may not be so significant. It is observed that when the operating speed increases, the heat transfer effect becomes less significant but the COP drops significantly. Additionally, it is found out that when the slender ratio increases, the heat transfer effect becomes greater but the COP drops significantly. Lastly, it can be concluded that the effect of slender ratio and operating speed on the performance of CVEC is more significant than that of heat transfer. Bachelor of Engineering (Mechanical Engineering) 2016-06-01T08:56:25Z 2016-06-01T08:56:25Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/68808 en Nanyang Technological University 95 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Chong, Yue Kin
Heat transfer study of novel cross vane expander-compressor unit
description With the growing concern of global warming, substantial efforts were made to improve energy efficiency and environmental friendliness of refrigeration systems. In 2014, a new type of expander-compressor unit called Cross Vane Expander-Compressor (CVEC) has been invented by Yap et al. [1]. A mathematical model that comprises of geometrical model, thermodynamics model and etc. is developed and simulated to study the working performance of CVEC. However, it is noticed that heat transfer is yet not taken into account of the mathematical model. In this project, a heat transfer model is developed and integrated into the mathematical model of CVEC to study the effect of heat transfer on CVEC performance. The theoretical simulation results shows that a specific suction valve angle of the expander fits only a particular operating condition. Failure to design the suction valve opening angle according to the operating condition would result in under or over-expansion of the expander discharge fluid. Some suggestions are then given to overcome this problem. Moreover, it is found out that the heat transfer rate increases significantly as the thermal conductivity of the expander-compressor unit increases but the COP is not greatly affected. This result suggests that the effects of heat transfer to the performance of CVEC may not be so significant. It is observed that when the operating speed increases, the heat transfer effect becomes less significant but the COP drops significantly. Additionally, it is found out that when the slender ratio increases, the heat transfer effect becomes greater but the COP drops significantly. Lastly, it can be concluded that the effect of slender ratio and operating speed on the performance of CVEC is more significant than that of heat transfer.
author2 Ooi Kim Tiow
author_facet Ooi Kim Tiow
Chong, Yue Kin
format Final Year Project
author Chong, Yue Kin
author_sort Chong, Yue Kin
title Heat transfer study of novel cross vane expander-compressor unit
title_short Heat transfer study of novel cross vane expander-compressor unit
title_full Heat transfer study of novel cross vane expander-compressor unit
title_fullStr Heat transfer study of novel cross vane expander-compressor unit
title_full_unstemmed Heat transfer study of novel cross vane expander-compressor unit
title_sort heat transfer study of novel cross vane expander-compressor unit
publishDate 2016
url http://hdl.handle.net/10356/68808
_version_ 1759853040899194880