Study on technical requirements for distributed generators connecting to power grid

Distributed generation or on-site generation is expected to increase over time with the focus shifting towards energy efficient, sustainable, and reliable means of generating electricity. In order to ensure that the integration of distributed generators does not cause any instability, the power grid...

Full description

Saved in:
Bibliographic Details
Main Author: Munukutla, Sruti Keerti
Other Authors: Abhishek Ukil
Format: Theses and Dissertations
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/68995
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-68995
record_format dspace
spelling sg-ntu-dr.10356-689952023-07-04T15:05:07Z Study on technical requirements for distributed generators connecting to power grid Munukutla, Sruti Keerti Abhishek Ukil School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering Distributed generation or on-site generation is expected to increase over time with the focus shifting towards energy efficient, sustainable, and reliable means of generating electricity. In order to ensure that the integration of distributed generators does not cause any instability, the power grid companies require that the generator equipment follow certain rules and requirements set by them in the form of "Grid codes". These requirements differ from one country to another due to differences in the topology of the network and hence, study of generator connection requirements cannot be generalized. This thesis deals with the analysis of critical requirements of synchronous generator connection requirements for two grid codes, namely German Grid code & Technical rules defined by Western Power Australia. Among all the requirements, Low voltage ride through capability requires that the connected generator maintain its connection if the voltage at the point of common coupling is above the required Low Voltage Ride Through profile when fault occurs in the power grid. This is one of the most demanding requirements and is hence important to analyse the LVRT characteristics during the modelling phase of a generator system. To study the strong & weak grid conditions, a single machine connected to an infinite bus model was developed. The simulations were performed using MATLAB Simulink. Effects of transmission line lengths, meshed & radial configurations on the transient stability and LVRT capability were assessed for various ratings of generators for grid compliance studies. The observations of the simulations are presented and discussed. The results of the cases studies show that meshed configuration performs better with respect to transient stability. Master of Science (Power Engineering) 2016-08-23T03:44:35Z 2016-08-23T03:44:35Z 2016 Thesis http://hdl.handle.net/10356/68995 en 113 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Munukutla, Sruti Keerti
Study on technical requirements for distributed generators connecting to power grid
description Distributed generation or on-site generation is expected to increase over time with the focus shifting towards energy efficient, sustainable, and reliable means of generating electricity. In order to ensure that the integration of distributed generators does not cause any instability, the power grid companies require that the generator equipment follow certain rules and requirements set by them in the form of "Grid codes". These requirements differ from one country to another due to differences in the topology of the network and hence, study of generator connection requirements cannot be generalized. This thesis deals with the analysis of critical requirements of synchronous generator connection requirements for two grid codes, namely German Grid code & Technical rules defined by Western Power Australia. Among all the requirements, Low voltage ride through capability requires that the connected generator maintain its connection if the voltage at the point of common coupling is above the required Low Voltage Ride Through profile when fault occurs in the power grid. This is one of the most demanding requirements and is hence important to analyse the LVRT characteristics during the modelling phase of a generator system. To study the strong & weak grid conditions, a single machine connected to an infinite bus model was developed. The simulations were performed using MATLAB Simulink. Effects of transmission line lengths, meshed & radial configurations on the transient stability and LVRT capability were assessed for various ratings of generators for grid compliance studies. The observations of the simulations are presented and discussed. The results of the cases studies show that meshed configuration performs better with respect to transient stability.
author2 Abhishek Ukil
author_facet Abhishek Ukil
Munukutla, Sruti Keerti
format Theses and Dissertations
author Munukutla, Sruti Keerti
author_sort Munukutla, Sruti Keerti
title Study on technical requirements for distributed generators connecting to power grid
title_short Study on technical requirements for distributed generators connecting to power grid
title_full Study on technical requirements for distributed generators connecting to power grid
title_fullStr Study on technical requirements for distributed generators connecting to power grid
title_full_unstemmed Study on technical requirements for distributed generators connecting to power grid
title_sort study on technical requirements for distributed generators connecting to power grid
publishDate 2016
url http://hdl.handle.net/10356/68995
_version_ 1772827180636569600