Improvement of control function for energy management system

An Air-Conditioning and Mechanical Ventilation (ACMV) system is one of the most important technological advancements to arise from the industrial revolution. A building energy management system is involved in the control of all aspects of building automation and not only in the ACMV system, such con...

Full description

Saved in:
Bibliographic Details
Main Author: Chakaravarthi Narasimman Srivathsan
Other Authors: School of Electrical and Electronic Engineering
Format: Theses and Dissertations
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/69517
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-69517
record_format dspace
spelling sg-ntu-dr.10356-695172023-07-04T15:41:32Z Improvement of control function for energy management system Chakaravarthi Narasimman Srivathsan School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering An Air-Conditioning and Mechanical Ventilation (ACMV) system is one of the most important technological advancements to arise from the industrial revolution. A building energy management system is involved in the control of all aspects of building automation and not only in the ACMV system, such conformity is the main reason for its ubiquity. It is a software patch that works over the normal automation software which helps monitor and control the energy usage in the system. The building energy management system is heavily concerned with the working of the ACMV system since it is the major area of energy consumption. The betterment of the control function for a building energy management system is the problem at hand. The technique followed to optimise the control function of the energy management system is by narrowing the outlook to the area of major energy consumption. The chiller is responsible for the majority of power consumption in the ACMV system, which in turn makes it the single largest contributor to the energy loss. In order to improve the performance of the energy management system the chiller staging algorithm is analysed for optimality. If the chiller staging algorithm employed is the most optimal then the overall energy consumption is drastically reduced. The specific contribution to the realm of building energy management systems here is the focus strained on the chiller staging algorithm. The cooling load of a building is modelled as a function of a set of input parameters which can be chosen depending upon the weather conditions of the region and the sensors available in the building. The model is developed with the data from the BSTAR model development in Nanyang Technological University. The staging data obtained from the predicted cooling load is then analysed to determine if the staging algorithm implemented is optimal in nature. Thus verification of the chiller staging algorithm leads to the use of the optimal algorithm, which in turn improves the functioning of the control system of the building energy management system. This method is different from other such existing techniques in that it can be easily implemented and can be adapted to suit different kinds of structures. The basic framework is such that improvements to suit specific applications can be implemented easily. The model is developed using four different techniques to provide a choice for the user so as to utilise the best model for the system under consideration. This improvement to the energy management system tackles the problem at its root and improves the overall efficacy of the same a lot more effectively than its contemporary solutions. Master of Science (Computer Control and Automation) 2017-02-01T03:45:35Z 2017-02-01T03:45:35Z 2017 Thesis http://hdl.handle.net/10356/69517 en 70 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Chakaravarthi Narasimman Srivathsan
Improvement of control function for energy management system
description An Air-Conditioning and Mechanical Ventilation (ACMV) system is one of the most important technological advancements to arise from the industrial revolution. A building energy management system is involved in the control of all aspects of building automation and not only in the ACMV system, such conformity is the main reason for its ubiquity. It is a software patch that works over the normal automation software which helps monitor and control the energy usage in the system. The building energy management system is heavily concerned with the working of the ACMV system since it is the major area of energy consumption. The betterment of the control function for a building energy management system is the problem at hand. The technique followed to optimise the control function of the energy management system is by narrowing the outlook to the area of major energy consumption. The chiller is responsible for the majority of power consumption in the ACMV system, which in turn makes it the single largest contributor to the energy loss. In order to improve the performance of the energy management system the chiller staging algorithm is analysed for optimality. If the chiller staging algorithm employed is the most optimal then the overall energy consumption is drastically reduced. The specific contribution to the realm of building energy management systems here is the focus strained on the chiller staging algorithm. The cooling load of a building is modelled as a function of a set of input parameters which can be chosen depending upon the weather conditions of the region and the sensors available in the building. The model is developed with the data from the BSTAR model development in Nanyang Technological University. The staging data obtained from the predicted cooling load is then analysed to determine if the staging algorithm implemented is optimal in nature. Thus verification of the chiller staging algorithm leads to the use of the optimal algorithm, which in turn improves the functioning of the control system of the building energy management system. This method is different from other such existing techniques in that it can be easily implemented and can be adapted to suit different kinds of structures. The basic framework is such that improvements to suit specific applications can be implemented easily. The model is developed using four different techniques to provide a choice for the user so as to utilise the best model for the system under consideration. This improvement to the energy management system tackles the problem at its root and improves the overall efficacy of the same a lot more effectively than its contemporary solutions.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Chakaravarthi Narasimman Srivathsan
format Theses and Dissertations
author Chakaravarthi Narasimman Srivathsan
author_sort Chakaravarthi Narasimman Srivathsan
title Improvement of control function for energy management system
title_short Improvement of control function for energy management system
title_full Improvement of control function for energy management system
title_fullStr Improvement of control function for energy management system
title_full_unstemmed Improvement of control function for energy management system
title_sort improvement of control function for energy management system
publishDate 2017
url http://hdl.handle.net/10356/69517
_version_ 1772828051187433472