Implementation of unified power quality conditioner with distributed generation for improving power quality

The increasing usage of loads that contribute towards undesirable power quality problems leads to the need for researchers to search for viable solutions to overcome them. An example of such loads is non-linear loads that inject harmonic components into a power system. This may result in distorted w...

Full description

Saved in:
Bibliographic Details
Main Author: Lee, Shaun Guo Hao
Other Authors: Gooi Hoay Beng
Format: Final Year Project
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/70736
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-70736
record_format dspace
spelling sg-ntu-dr.10356-707362023-07-07T17:20:57Z Implementation of unified power quality conditioner with distributed generation for improving power quality Lee, Shaun Guo Hao Gooi Hoay Beng School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Electric power The increasing usage of loads that contribute towards undesirable power quality problems leads to the need for researchers to search for viable solutions to overcome them. An example of such loads is non-linear loads that inject harmonic components into a power system. This may result in distorted waveforms experienced at the supply of the system, polluting the entire network and thus, affecting other consumers sharing the same point of common coupling (PCC). A comprehensive review is done on existing compensating devices known in the industry. A study is conducted with more emphasis on Unified Power Quality Conditioner (UPQC) and its control methodology. A UPQC is an integrated device comprising a shunt and series active filter connected via a DC link capacitor that can resolve significant poor power quality problems by means of current and voltage compensations respectively. The working principles of the shunt and series converters in a UPQC and their corresponding control algorithms are designed in MATLAB/Simulink to analyse their performances independently when different types of loads are connected. Thereafter, they are integrated together and coupled with a Distributed Generation (DG) for a complete analysis of UPQC with DG. Another topology for the UPQC will also be discussed where compensation is done through reactive power control (UPQC-Q). Validation of the UPQCs operating performances is done by conducting experiments on the Triphase power module and simulation studies in Simulink. From the results taken, the effectiveness of the proposed UPQC in its ability to resolve major power quality problems satisfactorily is verified. The experimental setup introduces external factors like losses and noise that can affect the results. Overall, the results are still within the acceptable limits. Bachelor of Engineering 2017-05-09T08:41:08Z 2017-05-09T08:41:08Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/70736 en Nanyang Technological University 70 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering::Electric power
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Electric power
Lee, Shaun Guo Hao
Implementation of unified power quality conditioner with distributed generation for improving power quality
description The increasing usage of loads that contribute towards undesirable power quality problems leads to the need for researchers to search for viable solutions to overcome them. An example of such loads is non-linear loads that inject harmonic components into a power system. This may result in distorted waveforms experienced at the supply of the system, polluting the entire network and thus, affecting other consumers sharing the same point of common coupling (PCC). A comprehensive review is done on existing compensating devices known in the industry. A study is conducted with more emphasis on Unified Power Quality Conditioner (UPQC) and its control methodology. A UPQC is an integrated device comprising a shunt and series active filter connected via a DC link capacitor that can resolve significant poor power quality problems by means of current and voltage compensations respectively. The working principles of the shunt and series converters in a UPQC and their corresponding control algorithms are designed in MATLAB/Simulink to analyse their performances independently when different types of loads are connected. Thereafter, they are integrated together and coupled with a Distributed Generation (DG) for a complete analysis of UPQC with DG. Another topology for the UPQC will also be discussed where compensation is done through reactive power control (UPQC-Q). Validation of the UPQCs operating performances is done by conducting experiments on the Triphase power module and simulation studies in Simulink. From the results taken, the effectiveness of the proposed UPQC in its ability to resolve major power quality problems satisfactorily is verified. The experimental setup introduces external factors like losses and noise that can affect the results. Overall, the results are still within the acceptable limits.
author2 Gooi Hoay Beng
author_facet Gooi Hoay Beng
Lee, Shaun Guo Hao
format Final Year Project
author Lee, Shaun Guo Hao
author_sort Lee, Shaun Guo Hao
title Implementation of unified power quality conditioner with distributed generation for improving power quality
title_short Implementation of unified power quality conditioner with distributed generation for improving power quality
title_full Implementation of unified power quality conditioner with distributed generation for improving power quality
title_fullStr Implementation of unified power quality conditioner with distributed generation for improving power quality
title_full_unstemmed Implementation of unified power quality conditioner with distributed generation for improving power quality
title_sort implementation of unified power quality conditioner with distributed generation for improving power quality
publishDate 2017
url http://hdl.handle.net/10356/70736
_version_ 1772827818563993600