The behaviour of precast concrete building to resist progressive collapse

Throughout the past century, there have been numerous structural collapse incidents all over the world. Progressive collapse is one of the most devastating types of structural collapse, usually resulting in hefty damages, serious injuries and even possibly endangering people’s life. This prompts res...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Wei Kai
Other Authors: Li Bing
Format: Final Year Project
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/71186
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-71186
record_format dspace
spelling sg-ntu-dr.10356-711862023-03-03T16:50:08Z The behaviour of precast concrete building to resist progressive collapse Lim, Wei Kai Li Bing School of Civil and Environmental Engineering DRNTU::Engineering::Civil engineering::Structures and design Throughout the past century, there have been numerous structural collapse incidents all over the world. Progressive collapse is one of the most devastating types of structural collapse, usually resulting in hefty damages, serious injuries and even possibly endangering people’s life. This prompts research works into improving the toughness of building structures in a bid to mitigate progressive collapse. This study examines the effects of connection types on the behaviour of precast concrete (PC) structures and its ability to mitigate progressive collapse. In this study, three one-third scaled beam-slab substructures comprising of a cast-in-place reinforced concrete (RC) specimen and two PC specimens are tested under pushdown loading regime. The PC slabs and PC beams are connected by a special link, which has been designed to improve the connection between them. This report presents the test results, which include the load-displacement curve, ultimate load capacity, ultimate deformation capacity and local strain. Thereafter, it discusses on the failure mode and mechanisms of load redistribution. From the test results, it is conclusive that the PC specimen with welded connections achieved brittle failure with the lowest ultimate load capacity and deformation capacity. The PC specimen with pinned connections has a large rotational ability which ensured that the specimen failed in a ductile manner, allowing substantial tensile membrane actions to develop in the topping layer even though the specimen has the lowest initial stiffness and has already achieved its first peak load capacity. Despite severe separation occurring between the PC slabs and beams, even at the maximum displacement of more than double that of the beam span, no PC slab collapsed. Bachelor of Engineering (Civil) 2017-05-15T06:59:06Z 2017-05-15T06:59:06Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/71186 en Nanyang Technological University 65 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Civil engineering::Structures and design
spellingShingle DRNTU::Engineering::Civil engineering::Structures and design
Lim, Wei Kai
The behaviour of precast concrete building to resist progressive collapse
description Throughout the past century, there have been numerous structural collapse incidents all over the world. Progressive collapse is one of the most devastating types of structural collapse, usually resulting in hefty damages, serious injuries and even possibly endangering people’s life. This prompts research works into improving the toughness of building structures in a bid to mitigate progressive collapse. This study examines the effects of connection types on the behaviour of precast concrete (PC) structures and its ability to mitigate progressive collapse. In this study, three one-third scaled beam-slab substructures comprising of a cast-in-place reinforced concrete (RC) specimen and two PC specimens are tested under pushdown loading regime. The PC slabs and PC beams are connected by a special link, which has been designed to improve the connection between them. This report presents the test results, which include the load-displacement curve, ultimate load capacity, ultimate deformation capacity and local strain. Thereafter, it discusses on the failure mode and mechanisms of load redistribution. From the test results, it is conclusive that the PC specimen with welded connections achieved brittle failure with the lowest ultimate load capacity and deformation capacity. The PC specimen with pinned connections has a large rotational ability which ensured that the specimen failed in a ductile manner, allowing substantial tensile membrane actions to develop in the topping layer even though the specimen has the lowest initial stiffness and has already achieved its first peak load capacity. Despite severe separation occurring between the PC slabs and beams, even at the maximum displacement of more than double that of the beam span, no PC slab collapsed.
author2 Li Bing
author_facet Li Bing
Lim, Wei Kai
format Final Year Project
author Lim, Wei Kai
author_sort Lim, Wei Kai
title The behaviour of precast concrete building to resist progressive collapse
title_short The behaviour of precast concrete building to resist progressive collapse
title_full The behaviour of precast concrete building to resist progressive collapse
title_fullStr The behaviour of precast concrete building to resist progressive collapse
title_full_unstemmed The behaviour of precast concrete building to resist progressive collapse
title_sort behaviour of precast concrete building to resist progressive collapse
publishDate 2017
url http://hdl.handle.net/10356/71186
_version_ 1759854034914639872