Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process

With an ever increasing world population, the demand for clean and safe drinking water also increases. As such, various disinfection techniques have been widely applied to tackle the problem of contaminated natural water sources and one such example is the use of membrane technology. However, membra...

Full description

Saved in:
Bibliographic Details
Main Author: Yeo, April Yun Xuan
Other Authors: Tuti Mariana Lim
Format: Final Year Project
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/71398
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-71398
record_format dspace
spelling sg-ntu-dr.10356-713982023-03-03T17:27:29Z Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process Yeo, April Yun Xuan Tuti Mariana Lim School of Civil and Environmental Engineering DRNTU::Engineering::Environmental engineering::Water supply With an ever increasing world population, the demand for clean and safe drinking water also increases. As such, various disinfection techniques have been widely applied to tackle the problem of contaminated natural water sources and one such example is the use of membrane technology. However, membranes are prone to biofouling and biofouling can potentially affect the treatment process. To prevent biofouling of membranes, water/wastewater should be pre- treated. In this study, the efficiency of using ozone advanced oxidation process was investigated for potential treatment of water spiked with contaminant. The bacterium model used was the wild type Pseudomonas aeruginosa bacterial strain PA01. Experiments using 4 different rates of ozone generation (100 mg/h, 200 mg/h, 300 mg/h and 400 mg/h) to inactivate a PA01 concentration of 8×106 CFU/ml were conducted to determine the most effective ozone generation rate. The inactivation efficiency of the different rates of ozone generation was calculated and the ozone generation rate of 400 mg/h was found to be the most efficient as 100% inactivation was reached within the fastest time of 10s. Experiments using an ozone generation rate of 400 mg/h as a control were then conducted with varying concentrations of PA01 to investigate the duration needed to achieve 100% inactivation. It was also found out that as contact time increased, inactivation efficiency also increased because there were less living cells over time. Therefore, the inactivation of Pseudomonas aeruginosa was found to be dependent on the disinfectant concentration and contact time. Bachelor of Engineering (Environmental Engineering) 2017-05-16T07:48:27Z 2017-05-16T07:48:27Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/71398 en Nanyang Technological University 51 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Environmental engineering::Water supply
spellingShingle DRNTU::Engineering::Environmental engineering::Water supply
Yeo, April Yun Xuan
Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process
description With an ever increasing world population, the demand for clean and safe drinking water also increases. As such, various disinfection techniques have been widely applied to tackle the problem of contaminated natural water sources and one such example is the use of membrane technology. However, membranes are prone to biofouling and biofouling can potentially affect the treatment process. To prevent biofouling of membranes, water/wastewater should be pre- treated. In this study, the efficiency of using ozone advanced oxidation process was investigated for potential treatment of water spiked with contaminant. The bacterium model used was the wild type Pseudomonas aeruginosa bacterial strain PA01. Experiments using 4 different rates of ozone generation (100 mg/h, 200 mg/h, 300 mg/h and 400 mg/h) to inactivate a PA01 concentration of 8×106 CFU/ml were conducted to determine the most effective ozone generation rate. The inactivation efficiency of the different rates of ozone generation was calculated and the ozone generation rate of 400 mg/h was found to be the most efficient as 100% inactivation was reached within the fastest time of 10s. Experiments using an ozone generation rate of 400 mg/h as a control were then conducted with varying concentrations of PA01 to investigate the duration needed to achieve 100% inactivation. It was also found out that as contact time increased, inactivation efficiency also increased because there were less living cells over time. Therefore, the inactivation of Pseudomonas aeruginosa was found to be dependent on the disinfectant concentration and contact time.
author2 Tuti Mariana Lim
author_facet Tuti Mariana Lim
Yeo, April Yun Xuan
format Final Year Project
author Yeo, April Yun Xuan
author_sort Yeo, April Yun Xuan
title Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process
title_short Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process
title_full Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process
title_fullStr Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process
title_full_unstemmed Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process
title_sort feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (ro) membrane biofouling using ozone process
publishDate 2017
url http://hdl.handle.net/10356/71398
_version_ 1759853746098012160