Experimental analysis for carryover elimination in liquid desiccant dehumidification system

In this project, we are going to test and improve a liquid desiccant dehumidification system in air quality aspects. The purpose is to guarantee the system is stable and meet the standard requirement. Normally, there are many factors can influence the output air quality in liquid desiccant dehumidif...

Full description

Saved in:
Bibliographic Details
Main Author: Ji, Yuan
Other Authors: Cai Wenjian
Format: Final Year Project
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/72033
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-72033
record_format dspace
spelling sg-ntu-dr.10356-720332023-07-07T17:19:14Z Experimental analysis for carryover elimination in liquid desiccant dehumidification system Ji, Yuan Cai Wenjian School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering In this project, we are going to test and improve a liquid desiccant dehumidification system in air quality aspects. The purpose is to guarantee the system is stable and meet the standard requirement. Normally, there are many factors can influence the output air quality in liquid desiccant dehumidification system, such as desiccant temperature or air flowrate. This project is mainly carried out in the form of experiments which specializes in comparative experiments to find the relationship between air quality and these factors. ICP-MS will gauge the sample to find out the concentration of desiccant in the air. The results of the experiments will then give the theoretical support to the system hardware improvement. Air filter and distributor pipe structure are two hardware improvement direction. Overall, this report is to show the details procedure and results of the experiments and the improved hardware design. In the future, more experiments need be carried out due to the more complicated design of the system. Bachelor of Engineering 2017-05-23T08:12:22Z 2017-05-23T08:12:22Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/72033 en Nanyang Technological University 61 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Ji, Yuan
Experimental analysis for carryover elimination in liquid desiccant dehumidification system
description In this project, we are going to test and improve a liquid desiccant dehumidification system in air quality aspects. The purpose is to guarantee the system is stable and meet the standard requirement. Normally, there are many factors can influence the output air quality in liquid desiccant dehumidification system, such as desiccant temperature or air flowrate. This project is mainly carried out in the form of experiments which specializes in comparative experiments to find the relationship between air quality and these factors. ICP-MS will gauge the sample to find out the concentration of desiccant in the air. The results of the experiments will then give the theoretical support to the system hardware improvement. Air filter and distributor pipe structure are two hardware improvement direction. Overall, this report is to show the details procedure and results of the experiments and the improved hardware design. In the future, more experiments need be carried out due to the more complicated design of the system.
author2 Cai Wenjian
author_facet Cai Wenjian
Ji, Yuan
format Final Year Project
author Ji, Yuan
author_sort Ji, Yuan
title Experimental analysis for carryover elimination in liquid desiccant dehumidification system
title_short Experimental analysis for carryover elimination in liquid desiccant dehumidification system
title_full Experimental analysis for carryover elimination in liquid desiccant dehumidification system
title_fullStr Experimental analysis for carryover elimination in liquid desiccant dehumidification system
title_full_unstemmed Experimental analysis for carryover elimination in liquid desiccant dehumidification system
title_sort experimental analysis for carryover elimination in liquid desiccant dehumidification system
publishDate 2017
url http://hdl.handle.net/10356/72033
_version_ 1772826289463361536