Digital signal processor system for body pressure monitoring device

With the growing focuses on the diabetic foot ulceration, corresponding biomedical devices have become more and more popular. The plantar pressure is a crucial parameter to help patients monitor the walking posture for themselves. A smart sock plantar pressure measurement system was proposed which i...

Full description

Saved in:
Bibliographic Details
Main Author: Li, Yuanbo
Other Authors: Goh Wang Ling
Format: Theses and Dissertations
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/72583
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-72583
record_format dspace
spelling sg-ntu-dr.10356-725832023-07-04T16:05:28Z Digital signal processor system for body pressure monitoring device Li, Yuanbo Goh Wang Ling School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering With the growing focuses on the diabetic foot ulceration, corresponding biomedical devices have become more and more popular. The plantar pressure is a crucial parameter to help patients monitor the walking posture for themselves. A smart sock plantar pressure measurement system was proposed which included pressure sampling circuit, signal processing system and communication with mobile devices. This dissertation focused on the signal processing system design. In order to sample more accurate data, multi sensor channels were designed, which needed a switching control in a fixed frequency. Consequently, a Verilog code for switching control was created. In the meantime, simulation and test with PCB were operated to verify the function. Likewise, the data sampled by the circuit needed to be converted to the digital signal in serial. So an ADC with embedded SPI was used. The Verilog code for SPI control was created. In the meantime, simulation and test with the front-end circuit were operated to verify the function. Lastly, in this stage of the project, a wired communication design was done. The FPGA with UART-USB bridge was used and the Verilog code of UART transmitter was applied. Simulation and test with PC were finished to verify the function. In the future work, a wireless communication will be adopted like Bluetooth. And the error analysis will be further realized to acquire more accurate data. Furthermore, more complex data analysis will be performed to provide users more sufficient pressure information. Master of Science (Electronics) 2017-08-29T06:34:25Z 2017-08-29T06:34:25Z 2017 Thesis http://hdl.handle.net/10356/72583 en 58 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Li, Yuanbo
Digital signal processor system for body pressure monitoring device
description With the growing focuses on the diabetic foot ulceration, corresponding biomedical devices have become more and more popular. The plantar pressure is a crucial parameter to help patients monitor the walking posture for themselves. A smart sock plantar pressure measurement system was proposed which included pressure sampling circuit, signal processing system and communication with mobile devices. This dissertation focused on the signal processing system design. In order to sample more accurate data, multi sensor channels were designed, which needed a switching control in a fixed frequency. Consequently, a Verilog code for switching control was created. In the meantime, simulation and test with PCB were operated to verify the function. Likewise, the data sampled by the circuit needed to be converted to the digital signal in serial. So an ADC with embedded SPI was used. The Verilog code for SPI control was created. In the meantime, simulation and test with the front-end circuit were operated to verify the function. Lastly, in this stage of the project, a wired communication design was done. The FPGA with UART-USB bridge was used and the Verilog code of UART transmitter was applied. Simulation and test with PC were finished to verify the function. In the future work, a wireless communication will be adopted like Bluetooth. And the error analysis will be further realized to acquire more accurate data. Furthermore, more complex data analysis will be performed to provide users more sufficient pressure information.
author2 Goh Wang Ling
author_facet Goh Wang Ling
Li, Yuanbo
format Theses and Dissertations
author Li, Yuanbo
author_sort Li, Yuanbo
title Digital signal processor system for body pressure monitoring device
title_short Digital signal processor system for body pressure monitoring device
title_full Digital signal processor system for body pressure monitoring device
title_fullStr Digital signal processor system for body pressure monitoring device
title_full_unstemmed Digital signal processor system for body pressure monitoring device
title_sort digital signal processor system for body pressure monitoring device
publishDate 2017
url http://hdl.handle.net/10356/72583
_version_ 1772825663962611712