Lignin-based sensor for heavy metal analysis in water

In this work, a conductive polymer polypyrrole (PPy) solely and PPy containing a complex organic polymer kraft lignin in its structure, were exploited as an ion to electron transducer in a solid contact lead(II) ion selective electrode (ISE) design/construction. PPy and PPy/lignin layers of differen...

Full description

Saved in:
Bibliographic Details
Main Author: Tan, Perry Soon Ming
Other Authors: Grzegorz Lisak
Format: Final Year Project
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/72921
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-72921
record_format dspace
spelling sg-ntu-dr.10356-729212023-03-03T17:23:02Z Lignin-based sensor for heavy metal analysis in water Tan, Perry Soon Ming Grzegorz Lisak School of Civil and Environmental Engineering DRNTU::Engineering::Environmental engineering In this work, a conductive polymer polypyrrole (PPy) solely and PPy containing a complex organic polymer kraft lignin in its structure, were exploited as an ion to electron transducer in a solid contact lead(II) ion selective electrode (ISE) design/construction. PPy and PPy/lignin layers of different thickness (200, 500, and 1000, respectively) and lignin concentration (0.5, 1, and 2 mg/ml, respectively) were electro-polymerized on glassy carbon electrodes and with/without lead(II) ion selective membrane, casted on the surface to allow only Pb2+ ions migrate through the membrane, studied by different electrochemical methods. First of all, fundamental electrochemical properties, e.g., layer electric capacitivity, lignin redox activity, potential stability in terms of applied current (polarization), gas influence (acidifying and oxidative effect) of PPy and PPy/lignin layers solely (without the lead(II) ion selective membrane casted) were investigated and compared. Secondly, PPy and PPy/lignin layers, with and without the lead(II) ion selective membrane casted on top, were exploited in potentiometric measurements for lead(II) ion concentration determination in the concentration range from 10-7 to 10-1 M of Pb(NO3)2 in both buffered (pH 4) and un-buffered (pH varying between 7 to 4) solutions in order to optimize lead(II) ion concentration determination and improve the detection limit. It was found that the deposition of the lead(II) ion selective membrane lowered the detection limit when using both PPy and PPy/lignin-based electrodes since the membrane protected the polymer layers from the negative solution effect as well as enabled selective lead(II) ion penetration through the membrane. No effect of the presence of lignin within PPy structure was observed in terms of lead(II) ion concentration determination. Bachelor of Engineering (Environmental Engineering) 2017-12-12T09:02:40Z 2017-12-12T09:02:40Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/72921 en Nanyang Technological University 66 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Environmental engineering
spellingShingle DRNTU::Engineering::Environmental engineering
Tan, Perry Soon Ming
Lignin-based sensor for heavy metal analysis in water
description In this work, a conductive polymer polypyrrole (PPy) solely and PPy containing a complex organic polymer kraft lignin in its structure, were exploited as an ion to electron transducer in a solid contact lead(II) ion selective electrode (ISE) design/construction. PPy and PPy/lignin layers of different thickness (200, 500, and 1000, respectively) and lignin concentration (0.5, 1, and 2 mg/ml, respectively) were electro-polymerized on glassy carbon electrodes and with/without lead(II) ion selective membrane, casted on the surface to allow only Pb2+ ions migrate through the membrane, studied by different electrochemical methods. First of all, fundamental electrochemical properties, e.g., layer electric capacitivity, lignin redox activity, potential stability in terms of applied current (polarization), gas influence (acidifying and oxidative effect) of PPy and PPy/lignin layers solely (without the lead(II) ion selective membrane casted) were investigated and compared. Secondly, PPy and PPy/lignin layers, with and without the lead(II) ion selective membrane casted on top, were exploited in potentiometric measurements for lead(II) ion concentration determination in the concentration range from 10-7 to 10-1 M of Pb(NO3)2 in both buffered (pH 4) and un-buffered (pH varying between 7 to 4) solutions in order to optimize lead(II) ion concentration determination and improve the detection limit. It was found that the deposition of the lead(II) ion selective membrane lowered the detection limit when using both PPy and PPy/lignin-based electrodes since the membrane protected the polymer layers from the negative solution effect as well as enabled selective lead(II) ion penetration through the membrane. No effect of the presence of lignin within PPy structure was observed in terms of lead(II) ion concentration determination.
author2 Grzegorz Lisak
author_facet Grzegorz Lisak
Tan, Perry Soon Ming
format Final Year Project
author Tan, Perry Soon Ming
author_sort Tan, Perry Soon Ming
title Lignin-based sensor for heavy metal analysis in water
title_short Lignin-based sensor for heavy metal analysis in water
title_full Lignin-based sensor for heavy metal analysis in water
title_fullStr Lignin-based sensor for heavy metal analysis in water
title_full_unstemmed Lignin-based sensor for heavy metal analysis in water
title_sort lignin-based sensor for heavy metal analysis in water
publishDate 2017
url http://hdl.handle.net/10356/72921
_version_ 1759853337874792448