Removal of natural organic matter using hybrid oxidation reactor

Untreated wastewater was recycled in Singapore through treatment processes in water reclamation plants and NEWater plant. These treated wastewater are then directed to industry uses and local catchment reservoirs. However, wastewater contains natural organic matter which mainly comprises of humic ac...

Full description

Saved in:
Bibliographic Details
Main Author: Guan, Zhihua
Other Authors: Sun Delai, Darren
Format: Final Year Project
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/73046
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-73046
record_format dspace
spelling sg-ntu-dr.10356-730462023-03-03T16:54:22Z Removal of natural organic matter using hybrid oxidation reactor Guan, Zhihua Sun Delai, Darren School of Civil and Environmental Engineering DRNTU::Engineering::Environmental engineering Untreated wastewater was recycled in Singapore through treatment processes in water reclamation plants and NEWater plant. These treated wastewater are then directed to industry uses and local catchment reservoirs. However, wastewater contains natural organic matter which mainly comprises of humic acid that can lead to lower system performance of the membrane technology used in NEWater plants. Thus, this study aims to investigate the efficiency of using ozone in the removal of humic acid from in aqueous solution. In this study, a hybrid oxidation reactor was first designed and ozone was bubbled into the humic acid solution through an air stone. Humic acid stock solution was prepared and 20 times dilution with deionized water was used as influent for the hybrid oxidation reactor with an initial total organic carbon of about 30 mg/L. Several experiments (ozonation of humic acid solution without buffer, ozonation of humic acid solution with buffer, ozonation of humic acid solution at low pH, ozonation of humic acid solution at high pH ) with duration of 120 mins was conducted and the samples are collected at intervals of 20 mins. Total organic carbon and colour of the samples was recorded and studied. Ozonation of humic acid has achieved a removal rate of at least 80% for colour436 and a removal rate of about 15% to 25% was achieved for total organic carbon. It was found that the concentration of ozone is the limiting agent in this study. Bachelor of Engineering (Environmental Engineering) 2017-12-27T03:04:42Z 2017-12-27T03:04:42Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/73046 en Nanyang Technological University 35 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Environmental engineering
spellingShingle DRNTU::Engineering::Environmental engineering
Guan, Zhihua
Removal of natural organic matter using hybrid oxidation reactor
description Untreated wastewater was recycled in Singapore through treatment processes in water reclamation plants and NEWater plant. These treated wastewater are then directed to industry uses and local catchment reservoirs. However, wastewater contains natural organic matter which mainly comprises of humic acid that can lead to lower system performance of the membrane technology used in NEWater plants. Thus, this study aims to investigate the efficiency of using ozone in the removal of humic acid from in aqueous solution. In this study, a hybrid oxidation reactor was first designed and ozone was bubbled into the humic acid solution through an air stone. Humic acid stock solution was prepared and 20 times dilution with deionized water was used as influent for the hybrid oxidation reactor with an initial total organic carbon of about 30 mg/L. Several experiments (ozonation of humic acid solution without buffer, ozonation of humic acid solution with buffer, ozonation of humic acid solution at low pH, ozonation of humic acid solution at high pH ) with duration of 120 mins was conducted and the samples are collected at intervals of 20 mins. Total organic carbon and colour of the samples was recorded and studied. Ozonation of humic acid has achieved a removal rate of at least 80% for colour436 and a removal rate of about 15% to 25% was achieved for total organic carbon. It was found that the concentration of ozone is the limiting agent in this study.
author2 Sun Delai, Darren
author_facet Sun Delai, Darren
Guan, Zhihua
format Final Year Project
author Guan, Zhihua
author_sort Guan, Zhihua
title Removal of natural organic matter using hybrid oxidation reactor
title_short Removal of natural organic matter using hybrid oxidation reactor
title_full Removal of natural organic matter using hybrid oxidation reactor
title_fullStr Removal of natural organic matter using hybrid oxidation reactor
title_full_unstemmed Removal of natural organic matter using hybrid oxidation reactor
title_sort removal of natural organic matter using hybrid oxidation reactor
publishDate 2017
url http://hdl.handle.net/10356/73046
_version_ 1759856588717293568