Experiment study on the performance of temperature calibration methods
Different methods of calibration were experimented for Negative Temperature Coefficient thermistor. The different methods were beta formula, non-linear least square, inverse calibration and QR decomposition. To carry the experiment, a reference thermometer was used together with a thermistor to r...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2018
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/74769 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-74769 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-747692023-07-07T17:34:36Z Experiment study on the performance of temperature calibration methods Ngai, Xuan Dong Cai Wenjian School of Electrical and Electronic Engineering DRNTU::Engineering Different methods of calibration were experimented for Negative Temperature Coefficient thermistor. The different methods were beta formula, non-linear least square, inverse calibration and QR decomposition. To carry the experiment, a reference thermometer was used together with a thermistor to record the corresponding temperature and resistance. A digital multimeter was used to measure the resistance of the thermistor. They were placed in a thermo-flask with water so that the data points can be collected at different temperature, forming a non-linear relationship between temperature and resistance. The errors were compared on MATLAB and the method with the least errors were converted to C programming and downloaded to a micro controller for verification. Bachelor of Engineering 2018-05-24T01:27:23Z 2018-05-24T01:27:23Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/74769 en Nanyang Technological University 65 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering |
spellingShingle |
DRNTU::Engineering Ngai, Xuan Dong Experiment study on the performance of temperature calibration methods |
description |
Different methods of calibration were experimented for Negative Temperature Coefficient
thermistor. The different methods were beta formula, non-linear least square, inverse calibration
and QR decomposition. To carry the experiment, a reference thermometer was used together
with a thermistor to record the corresponding temperature and resistance. A digital multimeter
was used to measure the resistance of the thermistor. They were placed in a thermo-flask with
water so that the data points can be collected at different temperature, forming a non-linear
relationship between temperature and resistance. The errors were compared on MATLAB and
the method with the least errors were converted to C programming and downloaded to a
micro controller for verification. |
author2 |
Cai Wenjian |
author_facet |
Cai Wenjian Ngai, Xuan Dong |
format |
Final Year Project |
author |
Ngai, Xuan Dong |
author_sort |
Ngai, Xuan Dong |
title |
Experiment study on the performance of temperature calibration methods |
title_short |
Experiment study on the performance of temperature calibration methods |
title_full |
Experiment study on the performance of temperature calibration methods |
title_fullStr |
Experiment study on the performance of temperature calibration methods |
title_full_unstemmed |
Experiment study on the performance of temperature calibration methods |
title_sort |
experiment study on the performance of temperature calibration methods |
publishDate |
2018 |
url |
http://hdl.handle.net/10356/74769 |
_version_ |
1772827161638469632 |