Development of pump control system for acoustic integration chips

This report provides an in-depth insight into my final year project on developing a pump control system for the integrated acoustic chip. It gives a brief introduction of the project and the development phases it had went through before the whole system was established and tested out in actual exper...

Full description

Saved in:
Bibliographic Details
Main Author: Koh, Gregory Boon Leong
Other Authors: Liu Aiqun
Format: Final Year Project
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/74870
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-74870
record_format dspace
spelling sg-ntu-dr.10356-748702023-07-07T16:21:00Z Development of pump control system for acoustic integration chips Koh, Gregory Boon Leong Liu Aiqun School of Electrical and Electronic Engineering DRNTU::Engineering This report provides an in-depth insight into my final year project on developing a pump control system for the integrated acoustic chip. It gives a brief introduction of the project and the development phases it had went through before the whole system was established and tested out in actual experiment. The third chapter focuses on the development of the peristaltic pump system. It provides a description on the structure of the pump and the parameters that was selected into the system. Next, it covers the hardware that was essential to operate the system, the software that was required to control the operation of the pump and the function that was added into the system required for the experiment. The forth chapter covers the development of the syringe pump. It lists out the missing functions of the pump controller that was given by manufacturer. Enhancement has been done to improve the system. Lastly, the steps to test the system reliability. The fifth chapter narrows down to the integration of the pump system. Firstly, it tests out the functionality to prove that both pump could work simultaneously. After which, disadvantages were listed out and further improvisation was done to remove it. Additional features were added into the system controller so that user could monitor the experiment. The sixth chapter explains about the platform that was being built and designed. Its purpose was to mount all the components up so that user could easily carry the system within the lab to conduct experiment. Component was replaced so that everything could be mount. Finally, the pump control system was integrated with the chip and was used to test out in the experiments. Recommendation was discussed for future enhancement in the system. Bachelor of Engineering 2018-05-24T07:11:28Z 2018-05-24T07:11:28Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/74870 en Nanyang Technological University 67 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Koh, Gregory Boon Leong
Development of pump control system for acoustic integration chips
description This report provides an in-depth insight into my final year project on developing a pump control system for the integrated acoustic chip. It gives a brief introduction of the project and the development phases it had went through before the whole system was established and tested out in actual experiment. The third chapter focuses on the development of the peristaltic pump system. It provides a description on the structure of the pump and the parameters that was selected into the system. Next, it covers the hardware that was essential to operate the system, the software that was required to control the operation of the pump and the function that was added into the system required for the experiment. The forth chapter covers the development of the syringe pump. It lists out the missing functions of the pump controller that was given by manufacturer. Enhancement has been done to improve the system. Lastly, the steps to test the system reliability. The fifth chapter narrows down to the integration of the pump system. Firstly, it tests out the functionality to prove that both pump could work simultaneously. After which, disadvantages were listed out and further improvisation was done to remove it. Additional features were added into the system controller so that user could monitor the experiment. The sixth chapter explains about the platform that was being built and designed. Its purpose was to mount all the components up so that user could easily carry the system within the lab to conduct experiment. Component was replaced so that everything could be mount. Finally, the pump control system was integrated with the chip and was used to test out in the experiments. Recommendation was discussed for future enhancement in the system.
author2 Liu Aiqun
author_facet Liu Aiqun
Koh, Gregory Boon Leong
format Final Year Project
author Koh, Gregory Boon Leong
author_sort Koh, Gregory Boon Leong
title Development of pump control system for acoustic integration chips
title_short Development of pump control system for acoustic integration chips
title_full Development of pump control system for acoustic integration chips
title_fullStr Development of pump control system for acoustic integration chips
title_full_unstemmed Development of pump control system for acoustic integration chips
title_sort development of pump control system for acoustic integration chips
publishDate 2018
url http://hdl.handle.net/10356/74870
_version_ 1772825582110769152