Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers

Global trends in cooling demands grew rapidly during the past decades due to the higher quality of living standards and the increasing needs for the comfort of humans in this modern era. However, the conventional refrigeration system had impacted our environment in several ways, such as the global w...

Full description

Saved in:
Bibliographic Details
Main Author: Chua, Wei Cong
Other Authors: Anutosh Chakraborty
Format: Final Year Project
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/75452
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-75452
record_format dspace
spelling sg-ntu-dr.10356-754522023-03-04T18:29:50Z Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers Chua, Wei Cong Anutosh Chakraborty School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering Global trends in cooling demands grew rapidly during the past decades due to the higher quality of living standards and the increasing needs for the comfort of humans in this modern era. However, the conventional refrigeration system had impacted our environment in several ways, such as the global warming and ozone depletion. Adoption of adsorption cooling system provides a solution to these impacts as it is a more environmentally friendly and it promotes efficient energy usage as compared to the conventional vapour compression refrigeration system. This report investigated experimentally the performances and the working principles of a two-bed adsorption cooling system employing Silica gel and water as adsorbent-adsorbate pairs. Experiments were conducted to calculate the performance of the system in terms of cooling capacity and coefficient of performance (COP). Several key parameters such as the cycle time and the driving heat source temperatures are optimized to determine the highest COP and specific cooling capacity. Based on the results obtained, it can be deduced that the specific cooling power (SCP) and COP are increased with the increase in hot water inlet temperature. Besides, the optimum adsorption/desorption period for a cycle exists between 550 and 650 seconds. From the present set-up, the optimum COP and SCP are found to be 0.2 and 0.07 kW/kg for chilled water temperature of 10 °C. These findings would serve as a reference to others for further development of an adsorption chiller. It is recommended that more adsorbent beds could be added to the system to reduce the fluctuations of the chilled water temperatures. Bachelor of Engineering (Mechanical Engineering) 2018-05-31T06:27:17Z 2018-05-31T06:27:17Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/75452 en Nanyang Technological University 104 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering
spellingShingle DRNTU::Engineering::Mechanical engineering
Chua, Wei Cong
Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
description Global trends in cooling demands grew rapidly during the past decades due to the higher quality of living standards and the increasing needs for the comfort of humans in this modern era. However, the conventional refrigeration system had impacted our environment in several ways, such as the global warming and ozone depletion. Adoption of adsorption cooling system provides a solution to these impacts as it is a more environmentally friendly and it promotes efficient energy usage as compared to the conventional vapour compression refrigeration system. This report investigated experimentally the performances and the working principles of a two-bed adsorption cooling system employing Silica gel and water as adsorbent-adsorbate pairs. Experiments were conducted to calculate the performance of the system in terms of cooling capacity and coefficient of performance (COP). Several key parameters such as the cycle time and the driving heat source temperatures are optimized to determine the highest COP and specific cooling capacity. Based on the results obtained, it can be deduced that the specific cooling power (SCP) and COP are increased with the increase in hot water inlet temperature. Besides, the optimum adsorption/desorption period for a cycle exists between 550 and 650 seconds. From the present set-up, the optimum COP and SCP are found to be 0.2 and 0.07 kW/kg for chilled water temperature of 10 °C. These findings would serve as a reference to others for further development of an adsorption chiller. It is recommended that more adsorbent beds could be added to the system to reduce the fluctuations of the chilled water temperatures.
author2 Anutosh Chakraborty
author_facet Anutosh Chakraborty
Chua, Wei Cong
format Final Year Project
author Chua, Wei Cong
author_sort Chua, Wei Cong
title Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
title_short Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
title_full Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
title_fullStr Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
title_full_unstemmed Study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
title_sort study of heat driven adsorption chiller and compare its performance data with other adsorption chillers
publishDate 2018
url http://hdl.handle.net/10356/75452
_version_ 1759857601957330944