Punching shear strength of concrete slab with various corroded reinforcing bar
Reinforced concrete is very commonly used in all building structures as it provides high relative strength, high toleration of tensile strain, improves ductility and good bond to the concrete. The disadvantage of reinforced concrete is corrosion might take place over time due to exposure to chloride...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2018
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/76371 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-76371 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-763712023-03-03T17:10:26Z Punching shear strength of concrete slab with various corroded reinforcing bar Loh, Wen Rong Li Bing School of Civil and Environmental Engineering DRNTU::Engineering::Civil engineering::Geotechnical Reinforced concrete is very commonly used in all building structures as it provides high relative strength, high toleration of tensile strain, improves ductility and good bond to the concrete. The disadvantage of reinforced concrete is corrosion might take place over time due to exposure to chloride ions. Which results in a decrease of tensile strength. Steel corrosion happens when the oxidation on anode and reduction on cathode happens at the same rate concurrently. Corrosion of reinforced concrete is a serious issue especially building located at the coastal area. Over the years, there had been different studies on the punching shear strength of normal and high strength reinforced concrete slabs. This report focuses on the punching shear strength of 10 Grade 40 concrete slab with various corroded reinforcement. However, there are only result of 2 non-corroded slabs in this report for the time being as corrosion of the other slabs takes quite a long time. Punching shear tests of 2 Grade 40 concrete slabs with various flexural reinforcement are presented. The dimensions of the slab are 2.2 × 2.2 × 0.15 m with a supporting column of 0.2 × 0.2 × 0.2 m. The purpose of the tests is to investigate if code equations (ACI 318) for punching shear overestimate the actual punching shear strengths of slabs that are provided with a low amount of flexural reinforcement or low reinforcement ratio. Bachelor of Engineering (Civil) 2018-12-21T03:12:21Z 2018-12-21T03:12:21Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/76371 en Nanyang Technological University 51 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Civil engineering::Geotechnical |
spellingShingle |
DRNTU::Engineering::Civil engineering::Geotechnical Loh, Wen Rong Punching shear strength of concrete slab with various corroded reinforcing bar |
description |
Reinforced concrete is very commonly used in all building structures as it provides high relative strength, high toleration of tensile strain, improves ductility and good bond to the concrete. The disadvantage of reinforced concrete is corrosion might take place over time due to exposure to chloride ions. Which results in a decrease of tensile strength. Steel corrosion happens when the oxidation on anode and reduction on cathode happens at the same rate concurrently. Corrosion of reinforced concrete is a serious issue especially building located at the coastal area.
Over the years, there had been different studies on the punching shear strength of normal and high strength reinforced concrete slabs. This report focuses on the punching shear strength of 10 Grade 40 concrete slab with various corroded reinforcement. However, there are only result of 2 non-corroded slabs in this report for the time being as corrosion of the other slabs takes quite a long time.
Punching shear tests of 2 Grade 40 concrete slabs with various flexural reinforcement are presented. The dimensions of the slab are 2.2 × 2.2 × 0.15 m with a supporting column of 0.2 × 0.2 × 0.2 m. The purpose of the tests is to investigate if code equations (ACI 318) for punching shear overestimate the actual punching shear strengths of slabs that are provided with a low amount of flexural reinforcement or low reinforcement ratio. |
author2 |
Li Bing |
author_facet |
Li Bing Loh, Wen Rong |
format |
Final Year Project |
author |
Loh, Wen Rong |
author_sort |
Loh, Wen Rong |
title |
Punching shear strength of concrete slab with various corroded reinforcing bar |
title_short |
Punching shear strength of concrete slab with various corroded reinforcing bar |
title_full |
Punching shear strength of concrete slab with various corroded reinforcing bar |
title_fullStr |
Punching shear strength of concrete slab with various corroded reinforcing bar |
title_full_unstemmed |
Punching shear strength of concrete slab with various corroded reinforcing bar |
title_sort |
punching shear strength of concrete slab with various corroded reinforcing bar |
publishDate |
2018 |
url |
http://hdl.handle.net/10356/76371 |
_version_ |
1759856023360765952 |