Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection

In response to population growth, water resources are expected to aggravate. It is mainly due to human activities which slowly deteriorate the world’s environment. Through this action, the water quality around the world is degrading in quality. This would result in endangering human and ecosystem he...

Full description

Saved in:
Bibliographic Details
Main Author: Yeo, Alex Wei Hua
Other Authors: Miao Jianmin
Format: Final Year Project
Language:English
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/10356/76408
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-76408
record_format dspace
spelling sg-ntu-dr.10356-764082023-03-04T19:09:08Z Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection Yeo, Alex Wei Hua Miao Jianmin School of Mechanical and Aerospace Engineering MicroMachines Centre DRNTU::Engineering::Mechanical engineering In response to population growth, water resources are expected to aggravate. It is mainly due to human activities which slowly deteriorate the world’s environment. Through this action, the water quality around the world is degrading in quality. This would result in endangering human and ecosystem health furthermore raising the cost of water treatment. The threats that harm human health not only heavy metal but light metal as well. The consequence of light metal is not as serious as heavy metal, but it is also a concern for human health. Therefore, continuous monitoring of water quality is needed to identify water hardness and reducing this current issue. Conventional water quality measurement is a long process and require a long time to accomplish. The process starts from collecting water sample from various sources and transporting these samples to a laboratory for analysis. The result may be inaccurate due to different factors such as transportation duration and testing sequences. In recent years, compact chemical sensor can be considered as a potential replacement of conventional centralized testing equipment due to the development of portable, sensitive and miniaturized chemical sensor which shows great perspective in this area. Aside from chemical sensor, anodic stripping voltammetry technique can be used for on-site evaluation. The reason for this technique to be employ is due to its simple operation, high sensitivity and portability. Studies shows that chemically modified calixarene can be used to selectively bind variation of cationic and anionic. Therefore, some of the MEMS-based chemical sensors are further modified by drop-casting the working electrode with calixarene. Same concentration of calcium solution would be used to compare the sensitivity of non-modified sensor and modified sensor. The results of non-modified sensor and modified sensor for each experiment are presented and compared. After the collection of different results, the modified MEMS-based chemical sensor by drop-casting the working electrode with 3µL of p-tert-butylcalix(6)arene showed higher peak current as compared to non-modified sensor. This indicates a potential to modify the sensors to increase its sensitivity to be used for electrochemical applications in on-site light metal detection field. Bachelor of Engineering (Mechanical Engineering) 2019-01-07T08:38:45Z 2019-01-07T08:38:45Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/76408 en Nanyang Technological University 58 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering
spellingShingle DRNTU::Engineering::Mechanical engineering
Yeo, Alex Wei Hua
Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection
description In response to population growth, water resources are expected to aggravate. It is mainly due to human activities which slowly deteriorate the world’s environment. Through this action, the water quality around the world is degrading in quality. This would result in endangering human and ecosystem health furthermore raising the cost of water treatment. The threats that harm human health not only heavy metal but light metal as well. The consequence of light metal is not as serious as heavy metal, but it is also a concern for human health. Therefore, continuous monitoring of water quality is needed to identify water hardness and reducing this current issue. Conventional water quality measurement is a long process and require a long time to accomplish. The process starts from collecting water sample from various sources and transporting these samples to a laboratory for analysis. The result may be inaccurate due to different factors such as transportation duration and testing sequences. In recent years, compact chemical sensor can be considered as a potential replacement of conventional centralized testing equipment due to the development of portable, sensitive and miniaturized chemical sensor which shows great perspective in this area. Aside from chemical sensor, anodic stripping voltammetry technique can be used for on-site evaluation. The reason for this technique to be employ is due to its simple operation, high sensitivity and portability. Studies shows that chemically modified calixarene can be used to selectively bind variation of cationic and anionic. Therefore, some of the MEMS-based chemical sensors are further modified by drop-casting the working electrode with calixarene. Same concentration of calcium solution would be used to compare the sensitivity of non-modified sensor and modified sensor. The results of non-modified sensor and modified sensor for each experiment are presented and compared. After the collection of different results, the modified MEMS-based chemical sensor by drop-casting the working electrode with 3µL of p-tert-butylcalix(6)arene showed higher peak current as compared to non-modified sensor. This indicates a potential to modify the sensors to increase its sensitivity to be used for electrochemical applications in on-site light metal detection field.
author2 Miao Jianmin
author_facet Miao Jianmin
Yeo, Alex Wei Hua
format Final Year Project
author Yeo, Alex Wei Hua
author_sort Yeo, Alex Wei Hua
title Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection
title_short Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection
title_full Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection
title_fullStr Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection
title_full_unstemmed Fabrication and evaluation of MEMS thin-film AU working electrode for light metal detection
title_sort fabrication and evaluation of mems thin-film au working electrode for light metal detection
publishDate 2019
url http://hdl.handle.net/10356/76408
_version_ 1759852955203272704