A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study

Fractures of the femoral neck are injuries commonly sustained by elderly patients due to osteoporosis and unsteadiness of gait. Cannulated screws are widely used for internal fixation as a treatment for femoral neck fractures as it has the advantage of creating more accurate and reproducible fixatio...

Full description

Saved in:
Bibliographic Details
Main Author: Ho, Phoebe Zi Qing
Other Authors: Chou Siaw Meng
Format: Final Year Project
Language:English
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/10356/78773
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-78773
record_format dspace
spelling sg-ntu-dr.10356-787732023-03-04T19:14:42Z A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study Ho, Phoebe Zi Qing Chou Siaw Meng School of Mechanical and Aerospace Engineering Engineering::Mechanical engineering Fractures of the femoral neck are injuries commonly sustained by elderly patients due to osteoporosis and unsteadiness of gait. Cannulated screws are widely used for internal fixation as a treatment for femoral neck fractures as it has the advantage of creating more accurate and reproducible fixations. In prior studies, various conditions and configuration of screws have been investigated by correlating characteristics such as loading forces, stiffness and displacement. The aim of this project is to use finite element analysis (FEA) to simulate and study the difference between cannulated and non-cannulated screws used in the fixation of femoral neck fractures. In this study, a fixation using three parallel screws in an inverted triangular configuration was done on a fourth-generation synthetic composite femur with a Pauwel’s type II fracture. In this study, various conditions and settings were investigated and improved based on previous FEA models. The FEA model is continuously enhanced to increase its robustness and improve the results to be as close to the physical experiments as possible. Results from this study suggest that non-cannulated screws have higher load bearing capacity as compared to the cannulated screws. Bachelor of Engineering (Mechanical Engineering) 2019-06-27T01:32:32Z 2019-06-27T01:32:32Z 2019 Final Year Project (FYP) http://hdl.handle.net/10356/78773 en Nanyang Technological University 114 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Mechanical engineering
spellingShingle Engineering::Mechanical engineering
Ho, Phoebe Zi Qing
A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
description Fractures of the femoral neck are injuries commonly sustained by elderly patients due to osteoporosis and unsteadiness of gait. Cannulated screws are widely used for internal fixation as a treatment for femoral neck fractures as it has the advantage of creating more accurate and reproducible fixations. In prior studies, various conditions and configuration of screws have been investigated by correlating characteristics such as loading forces, stiffness and displacement. The aim of this project is to use finite element analysis (FEA) to simulate and study the difference between cannulated and non-cannulated screws used in the fixation of femoral neck fractures. In this study, a fixation using three parallel screws in an inverted triangular configuration was done on a fourth-generation synthetic composite femur with a Pauwel’s type II fracture. In this study, various conditions and settings were investigated and improved based on previous FEA models. The FEA model is continuously enhanced to increase its robustness and improve the results to be as close to the physical experiments as possible. Results from this study suggest that non-cannulated screws have higher load bearing capacity as compared to the cannulated screws.
author2 Chou Siaw Meng
author_facet Chou Siaw Meng
Ho, Phoebe Zi Qing
format Final Year Project
author Ho, Phoebe Zi Qing
author_sort Ho, Phoebe Zi Qing
title A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
title_short A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
title_full A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
title_fullStr A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
title_full_unstemmed A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
title_sort comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture – a finite element study
publishDate 2019
url http://hdl.handle.net/10356/78773
_version_ 1759857904708485120