Combined optical and acoustic resolution photoacoustic microscopy

Photoacoustic imaging is a fast growing in vivo imaging modality combining the optical absorption contrast and high spatial ultrasonic resolution. Using this technique deeper tissue penetration greater than optical mean free path (~1 mm in skin) is possible. Low resolution with deep penetration dept...

Full description

Saved in:
Bibliographic Details
Main Authors: Moothanchery, Mohesh, Pramanik, Manojit
Other Authors: School of Chemical and Biomedical Engineering
Format: Conference or Workshop Item
Language:English
Published: 2017
Subjects:
Online Access:https://hdl.handle.net/10356/80361
http://hdl.handle.net/10220/42152
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-80361
record_format dspace
spelling sg-ntu-dr.10356-803612023-12-29T06:44:13Z Combined optical and acoustic resolution photoacoustic microscopy Moothanchery, Mohesh Pramanik, Manojit School of Chemical and Biomedical Engineering Proceeding of SPIE 10064, Photons Plus Ultrasound: Imaging and Sensing 2017 Photoacoustic Imaging Optical resolution photoacoustic microscopy Photoacoustic imaging is a fast growing in vivo imaging modality combining the optical absorption contrast and high spatial ultrasonic resolution. Using this technique deeper tissue penetration greater than optical mean free path (~1 mm in skin) is possible. Low resolution with deep penetration depth is possible utilizing acoustic focusing and high resolution with shallow imaging depth can be possible by optical focusing using different photoacoustic microscopy (PAM) systems. Here, we present a combined/switchable optical resolution and acoustic resolution photoacoustic microscopy (OR-AR-PAM) system capable of both high resolution and low resolution deep tissue imaging on the same sample. Lateral resolution of 3.9 μm using optical focusing and lateral resolution of 57 μm using acoustic focusing was successfully demonstrated using the combined system. MOE (Min. of Education, S’pore) Published version 2017-03-06T03:15:02Z 2019-12-06T13:47:58Z 2017-03-06T03:15:02Z 2019-12-06T13:47:58Z 2017-03-01 2017 Conference Paper Moothanchery, M., & Pramanik, M. (2017). Combined optical and acoustic resolution photoacoustic microscopy. Proceeding of SPIE 10064, Photons Plus Ultrasound: Imaging and Sensing 2017, 100644P-. https://hdl.handle.net/10356/80361 http://hdl.handle.net/10220/42152 10.1117/12.2251258 196224 en © 2017 Society of Photo-optical Instrumentation Engineers (SPIE). This paper was published in Proceeding of SPIE 10064, Photons Plus Ultrasound: Imaging and Sensing 2017 and is made available as an electronic reprint (preprint) with permission of SPIE. The published version is available at: http://dx.doi.org/10.1117/12.2251258. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. 6 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Photoacoustic Imaging
Optical resolution photoacoustic microscopy
spellingShingle Photoacoustic Imaging
Optical resolution photoacoustic microscopy
Moothanchery, Mohesh
Pramanik, Manojit
Combined optical and acoustic resolution photoacoustic microscopy
description Photoacoustic imaging is a fast growing in vivo imaging modality combining the optical absorption contrast and high spatial ultrasonic resolution. Using this technique deeper tissue penetration greater than optical mean free path (~1 mm in skin) is possible. Low resolution with deep penetration depth is possible utilizing acoustic focusing and high resolution with shallow imaging depth can be possible by optical focusing using different photoacoustic microscopy (PAM) systems. Here, we present a combined/switchable optical resolution and acoustic resolution photoacoustic microscopy (OR-AR-PAM) system capable of both high resolution and low resolution deep tissue imaging on the same sample. Lateral resolution of 3.9 μm using optical focusing and lateral resolution of 57 μm using acoustic focusing was successfully demonstrated using the combined system.
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Moothanchery, Mohesh
Pramanik, Manojit
format Conference or Workshop Item
author Moothanchery, Mohesh
Pramanik, Manojit
author_sort Moothanchery, Mohesh
title Combined optical and acoustic resolution photoacoustic microscopy
title_short Combined optical and acoustic resolution photoacoustic microscopy
title_full Combined optical and acoustic resolution photoacoustic microscopy
title_fullStr Combined optical and acoustic resolution photoacoustic microscopy
title_full_unstemmed Combined optical and acoustic resolution photoacoustic microscopy
title_sort combined optical and acoustic resolution photoacoustic microscopy
publishDate 2017
url https://hdl.handle.net/10356/80361
http://hdl.handle.net/10220/42152
_version_ 1787136725308407808