Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
Z-sourcebeing an attractive option for buck-boost energy conversion in renewable system, this paper investigates the performances of the traditional boost converter and Z-source inverterfed by fuel cell as the dc source. The changes in the fuel cell utilization, stack consumption and efficiency of a...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2016
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/82263 http://hdl.handle.net/10220/39914 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7387071&newsearch=true&queryText=Performance%20evaluation%20of%20boost%20and%20Z-source%20converters%20for%20fuel%20cell%20application |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-82263 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-822632021-01-13T06:55:26Z Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application Roomi, Muhammad Mustafa Maswood, Ali Iftekhar Dehghani Tafti, Hossein School of Electrical and Electronic Engineering 2015 IEEE Innovative Smart Grid Technologies - Asia, ISGT Asia 2015 Energy Research Institute @ NTU (ERI@N) Proton Exchange Membrane Fuel Cell (PEMFC) Z-source inverter Boost converter Renewable energy Dc-dc/ac Z-sourcebeing an attractive option for buck-boost energy conversion in renewable system, this paper investigates the performances of the traditional boost converter and Z-source inverterfed by fuel cell as the dc source. The changes in the fuel cell utilization, stack consumption and efficiency of a 65kW fuel cell is studied by maintaining a constant fuel flow rate. The output voltage and current of the stack, dc output voltage, inverter output voltages and currents are evaluated for balanced and unbalanced load conditions. Simulations are carried out using Matlab/Simulinkand the results are presented. Accepted version 2016-02-01T06:42:25Z 2019-12-06T14:52:02Z 2016-02-01T06:42:25Z 2019-12-06T14:52:02Z 2015 Conference Paper Roomi, M. M., Maswood, A. I., & Dehghani Tafti, H. Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application. 2015 IEEE Innovative Smart Grid Technologies - Asia, ISGT Asia 2015, 1-7. https://hdl.handle.net/10356/82263 http://hdl.handle.net/10220/39914 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7387071&newsearch=true&queryText=Performance%20evaluation%20of%20boost%20and%20Z-source%20converters%20for%20fuel%20cell%20application 10.1109/ISGT-Asia.2015.7387071 en © 2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/ISGT-Asia.2015.7387071]. 6 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Proton Exchange Membrane Fuel Cell (PEMFC) Z-source inverter Boost converter Renewable energy Dc-dc/ac |
spellingShingle |
Proton Exchange Membrane Fuel Cell (PEMFC) Z-source inverter Boost converter Renewable energy Dc-dc/ac Roomi, Muhammad Mustafa Maswood, Ali Iftekhar Dehghani Tafti, Hossein Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application |
description |
Z-sourcebeing an attractive option for buck-boost energy conversion in renewable system, this paper investigates the performances of the traditional boost converter and Z-source inverterfed by fuel cell as the dc source. The changes in the fuel cell utilization, stack consumption and efficiency of a 65kW fuel cell is studied by maintaining a constant fuel flow rate. The output voltage and current of the stack, dc output voltage, inverter output voltages and currents are evaluated for balanced and unbalanced load conditions. Simulations are carried out using Matlab/Simulinkand the results are presented. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Roomi, Muhammad Mustafa Maswood, Ali Iftekhar Dehghani Tafti, Hossein |
format |
Conference or Workshop Item |
author |
Roomi, Muhammad Mustafa Maswood, Ali Iftekhar Dehghani Tafti, Hossein |
author_sort |
Roomi, Muhammad Mustafa |
title |
Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application |
title_short |
Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application |
title_full |
Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application |
title_fullStr |
Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application |
title_full_unstemmed |
Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application |
title_sort |
performance evaluation of boost and z-source converters for fuel cell application |
publishDate |
2016 |
url |
https://hdl.handle.net/10356/82263 http://hdl.handle.net/10220/39914 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7387071&newsearch=true&queryText=Performance%20evaluation%20of%20boost%20and%20Z-source%20converters%20for%20fuel%20cell%20application |
_version_ |