Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application

Z-sourcebeing an attractive option for buck-boost energy conversion in renewable system, this paper investigates the performances of the traditional boost converter and Z-source inverterfed by fuel cell as the dc source. The changes in the fuel cell utilization, stack consumption and efficiency of a...

Full description

Saved in:
Bibliographic Details
Main Authors: Roomi, Muhammad Mustafa, Maswood, Ali Iftekhar, Dehghani Tafti, Hossein
Other Authors: School of Electrical and Electronic Engineering
Format: Conference or Workshop Item
Language:English
Published: 2016
Subjects:
Online Access:https://hdl.handle.net/10356/82263
http://hdl.handle.net/10220/39914
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7387071&newsearch=true&queryText=Performance%20evaluation%20of%20boost%20and%20Z-source%20converters%20for%20fuel%20cell%20application
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-82263
record_format dspace
spelling sg-ntu-dr.10356-822632021-01-13T06:55:26Z Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application Roomi, Muhammad Mustafa Maswood, Ali Iftekhar Dehghani Tafti, Hossein School of Electrical and Electronic Engineering 2015 IEEE Innovative Smart Grid Technologies - Asia, ISGT Asia 2015 Energy Research Institute @ NTU (ERI@N) Proton Exchange Membrane Fuel Cell (PEMFC) Z-source inverter Boost converter Renewable energy Dc-dc/ac Z-sourcebeing an attractive option for buck-boost energy conversion in renewable system, this paper investigates the performances of the traditional boost converter and Z-source inverterfed by fuel cell as the dc source. The changes in the fuel cell utilization, stack consumption and efficiency of a 65kW fuel cell is studied by maintaining a constant fuel flow rate. The output voltage and current of the stack, dc output voltage, inverter output voltages and currents are evaluated for balanced and unbalanced load conditions. Simulations are carried out using Matlab/Simulinkand the results are presented. Accepted version 2016-02-01T06:42:25Z 2019-12-06T14:52:02Z 2016-02-01T06:42:25Z 2019-12-06T14:52:02Z 2015 Conference Paper Roomi, M. M., Maswood, A. I., & Dehghani Tafti, H. Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application. 2015 IEEE Innovative Smart Grid Technologies - Asia, ISGT Asia 2015, 1-7. https://hdl.handle.net/10356/82263 http://hdl.handle.net/10220/39914 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7387071&newsearch=true&queryText=Performance%20evaluation%20of%20boost%20and%20Z-source%20converters%20for%20fuel%20cell%20application 10.1109/ISGT-Asia.2015.7387071 en © 2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/ISGT-Asia.2015.7387071]. 6 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Proton Exchange Membrane Fuel Cell (PEMFC)
Z-source inverter
Boost converter
Renewable energy
Dc-dc/ac
spellingShingle Proton Exchange Membrane Fuel Cell (PEMFC)
Z-source inverter
Boost converter
Renewable energy
Dc-dc/ac
Roomi, Muhammad Mustafa
Maswood, Ali Iftekhar
Dehghani Tafti, Hossein
Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
description Z-sourcebeing an attractive option for buck-boost energy conversion in renewable system, this paper investigates the performances of the traditional boost converter and Z-source inverterfed by fuel cell as the dc source. The changes in the fuel cell utilization, stack consumption and efficiency of a 65kW fuel cell is studied by maintaining a constant fuel flow rate. The output voltage and current of the stack, dc output voltage, inverter output voltages and currents are evaluated for balanced and unbalanced load conditions. Simulations are carried out using Matlab/Simulinkand the results are presented.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Roomi, Muhammad Mustafa
Maswood, Ali Iftekhar
Dehghani Tafti, Hossein
format Conference or Workshop Item
author Roomi, Muhammad Mustafa
Maswood, Ali Iftekhar
Dehghani Tafti, Hossein
author_sort Roomi, Muhammad Mustafa
title Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
title_short Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
title_full Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
title_fullStr Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
title_full_unstemmed Performance Evaluation of Boost and Z-Source Converters for Fuel Cell Application
title_sort performance evaluation of boost and z-source converters for fuel cell application
publishDate 2016
url https://hdl.handle.net/10356/82263
http://hdl.handle.net/10220/39914
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7387071&newsearch=true&queryText=Performance%20evaluation%20of%20boost%20and%20Z-source%20converters%20for%20fuel%20cell%20application
_version_ 1690658395068039168