Seismic performance of RC short columns with light transverse reinforcement
The seismic behavior of reinforced concrete (RC) short columns with limited transverse reinforcement is investigated in this paper through an experimental program. The experimental program consists of four small-scale RC columns with an aspect ratio of 1.7, which are tested to the axial failure stag...
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2018
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/88405 http://hdl.handle.net/10220/45777 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-88405 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-884052020-03-07T11:43:37Z Seismic performance of RC short columns with light transverse reinforcement Tran, Cao Thanh Ngoc Li, Bing School of Civil and Environmental Engineering Reinforced Concrete Short Column DRNTU::Engineering::Civil engineering The seismic behavior of reinforced concrete (RC) short columns with limited transverse reinforcement is investigated in this paper through an experimental program. The experimental program consists of four small-scale RC columns with an aspect ratio of 1.7, which are tested to the axial failure stage. The cracking patterns, hysteretic responses, strains in reinforcing bars, displacement decomposition and cumulative energy dissipation of the tested specimens are reported in detail in the paper. The effects of column axial load are investigated to determine how this variable might influence the performance of the short columns with limited transverse reinforcement. Brittle shear failure was observed in all tested specimens. Beneficial and detrimental effects on the shear strength and drift ratio at axial failure of the test specimens due to the column axial load are found in the experimental program, respectively. Published version 2018-08-31T01:53:59Z 2019-12-06T17:02:35Z 2018-08-31T01:53:59Z 2019-12-06T17:02:35Z 2018 Journal Article Tran, C. T. N., & Li, B. (2018). Seismic performance of RC short columns with light transverse reinforcement. Structural Engineering and Mechanics, 67(1), 93-104. doi:10.12989/sem.2018.67.1.093 1225-4568 https://hdl.handle.net/10356/88405 http://hdl.handle.net/10220/45777 10.12989/sem.2018.67.1.093 en Structural Engineering and Mechanics © 2018 Techno-Press, Ltd. This paper was published in Structural Engineering and Mechanics and is made available as an electronic reprint (preprint) with permission of Techno-Press, Ltd. The published version is available at: [http://dx.doi.org/10.12989/sem.2018.67.1.093]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. 12 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
Reinforced Concrete Short Column DRNTU::Engineering::Civil engineering |
spellingShingle |
Reinforced Concrete Short Column DRNTU::Engineering::Civil engineering Tran, Cao Thanh Ngoc Li, Bing Seismic performance of RC short columns with light transverse reinforcement |
description |
The seismic behavior of reinforced concrete (RC) short columns with limited transverse reinforcement is investigated in this paper through an experimental program. The experimental program consists of four small-scale RC columns with an aspect ratio of 1.7, which are tested to the axial failure stage. The cracking patterns, hysteretic responses, strains in reinforcing bars, displacement decomposition and cumulative energy dissipation of the tested specimens are reported in detail in the paper. The effects of column axial load are investigated to determine how this variable might influence the performance of the short columns with limited transverse reinforcement. Brittle shear failure was observed in all tested specimens. Beneficial and detrimental effects on the shear strength and drift ratio at axial failure of the test specimens due to the column axial load are found in the experimental program, respectively. |
author2 |
School of Civil and Environmental Engineering |
author_facet |
School of Civil and Environmental Engineering Tran, Cao Thanh Ngoc Li, Bing |
format |
Article |
author |
Tran, Cao Thanh Ngoc Li, Bing |
author_sort |
Tran, Cao Thanh Ngoc |
title |
Seismic performance of RC short columns with light transverse reinforcement |
title_short |
Seismic performance of RC short columns with light transverse reinforcement |
title_full |
Seismic performance of RC short columns with light transverse reinforcement |
title_fullStr |
Seismic performance of RC short columns with light transverse reinforcement |
title_full_unstemmed |
Seismic performance of RC short columns with light transverse reinforcement |
title_sort |
seismic performance of rc short columns with light transverse reinforcement |
publishDate |
2018 |
url |
https://hdl.handle.net/10356/88405 http://hdl.handle.net/10220/45777 |
_version_ |
1681035258498121728 |