Near real-time detection of E. coli in reclaimed water

Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to pr...

Full description

Saved in:
Bibliographic Details
Main Authors: Sherchan, Samendra, Miles, Syreeta, Ikner, Luisa, Yu, Hye-Weon, Snyder, Shane Allen, Pepper, Ian L.
Other Authors: Nanyang Environment and Water Research Institute
Format: Article
Language:English
Published: 2018
Subjects:
Online Access:https://hdl.handle.net/10356/88440
http://hdl.handle.net/10220/45735
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-88440
record_format dspace
spelling sg-ntu-dr.10356-884402020-09-26T22:00:26Z Near real-time detection of E. coli in reclaimed water Sherchan, Samendra Miles, Syreeta Ikner, Luisa Yu, Hye-Weon Snyder, Shane Allen Pepper, Ian L. Nanyang Environment and Water Research Institute Water Quality Online Sensors DRNTU::Engineering::Environmental engineering Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to preclude potential adverse human health effects. Real-time detection of microbes presents unique problems which are dependent on the water quality of the test water, including parameters such as particulate content and turbidity, and natural organic matter content. In addition, microbes are unusual in that: (i) viability and culturability are not always synonymous; (ii) viability in water can be reduced by osmotic stress; and (iii) bacteria can invoke repair mechanisms in response to UV disinfection resulting in regrowth of bacterial populations. All these issues related to bacteria affect the efficacy of real-time detection for bacteria. Here we evaluate three different sensors suitable for specific water qualities. The sensor A is an on-line, real-time sensor that allows for the continuous monitoring of particulates (including microbial contaminants) using multi-angle-light scattering (MALS) technology. The sensor B is a microbial detection system that uses optical technique, Mie light scattering, for particle sizing and fluorescence emission for viable bacteria detection. The last sensor C was based on adenosine triphosphate (ATP) production. E. coli was used a model organism and out of all tested sensors, we found the sensor C to be the most accurate. It has a great potential as a surrogate parameter for microbial loads in test waters and be useful for process control in treatment trains. Published version 2018-08-29T07:25:21Z 2019-12-06T17:03:23Z 2018-08-29T07:25:21Z 2019-12-06T17:03:23Z 2018 Journal Article Sherchan, S., Miles, S., Ikner, L., Yu, H.-W., Snyder, S. A., & Pepper, I. L. (2018). Near real-time detection of E. coli in reclaimed water. Sensors, 18(7), 2303-. doi:10.3390/s18072303 1424-8220 https://hdl.handle.net/10356/88440 http://hdl.handle.net/10220/45735 10.3390/s18072303 en Sensors © 2018 The Author(s). Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). 10 p. application/pdf
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic Water Quality
Online Sensors
DRNTU::Engineering::Environmental engineering
spellingShingle Water Quality
Online Sensors
DRNTU::Engineering::Environmental engineering
Sherchan, Samendra
Miles, Syreeta
Ikner, Luisa
Yu, Hye-Weon
Snyder, Shane Allen
Pepper, Ian L.
Near real-time detection of E. coli in reclaimed water
description Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to preclude potential adverse human health effects. Real-time detection of microbes presents unique problems which are dependent on the water quality of the test water, including parameters such as particulate content and turbidity, and natural organic matter content. In addition, microbes are unusual in that: (i) viability and culturability are not always synonymous; (ii) viability in water can be reduced by osmotic stress; and (iii) bacteria can invoke repair mechanisms in response to UV disinfection resulting in regrowth of bacterial populations. All these issues related to bacteria affect the efficacy of real-time detection for bacteria. Here we evaluate three different sensors suitable for specific water qualities. The sensor A is an on-line, real-time sensor that allows for the continuous monitoring of particulates (including microbial contaminants) using multi-angle-light scattering (MALS) technology. The sensor B is a microbial detection system that uses optical technique, Mie light scattering, for particle sizing and fluorescence emission for viable bacteria detection. The last sensor C was based on adenosine triphosphate (ATP) production. E. coli was used a model organism and out of all tested sensors, we found the sensor C to be the most accurate. It has a great potential as a surrogate parameter for microbial loads in test waters and be useful for process control in treatment trains.
author2 Nanyang Environment and Water Research Institute
author_facet Nanyang Environment and Water Research Institute
Sherchan, Samendra
Miles, Syreeta
Ikner, Luisa
Yu, Hye-Weon
Snyder, Shane Allen
Pepper, Ian L.
format Article
author Sherchan, Samendra
Miles, Syreeta
Ikner, Luisa
Yu, Hye-Weon
Snyder, Shane Allen
Pepper, Ian L.
author_sort Sherchan, Samendra
title Near real-time detection of E. coli in reclaimed water
title_short Near real-time detection of E. coli in reclaimed water
title_full Near real-time detection of E. coli in reclaimed water
title_fullStr Near real-time detection of E. coli in reclaimed water
title_full_unstemmed Near real-time detection of E. coli in reclaimed water
title_sort near real-time detection of e. coli in reclaimed water
publishDate 2018
url https://hdl.handle.net/10356/88440
http://hdl.handle.net/10220/45735
_version_ 1681057918716215296