Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system

In a circular scanning photoacoustic computed tomography (PAT/PACT) system, a single-element ultrasound transducer (SUT) (rotates in full 360° around the sample) or a full-ring array transducer is used to acquire the photoacoustic (PA) data from the target object. SUT takes several minutes to acquir...

Full description

Saved in:
Bibliographic Details
Main Authors: Kalva, Sandeep Kumar, Hui, Zhe Zhi, Pramanik, Manojit
Other Authors: School of Chemical and Biomedical Engineering
Format: Article
Language:English
Published: 2018
Subjects:
Online Access:https://hdl.handle.net/10356/88609
http://hdl.handle.net/10220/44706
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-88609
record_format dspace
spelling sg-ntu-dr.10356-886092023-12-29T06:52:27Z Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system Kalva, Sandeep Kumar Hui, Zhe Zhi Pramanik, Manojit School of Chemical and Biomedical Engineering Image Reconstruction Techniques Photoacoustic Imaging In a circular scanning photoacoustic computed tomography (PAT/PACT) system, a single-element ultrasound transducer (SUT) (rotates in full 360° around the sample) or a full-ring array transducer is used to acquire the photoacoustic (PA) data from the target object. SUT takes several minutes to acquire the PA data, whereas the full-ring array transducer takes only few seconds. Hence, for real-time imaging, full-ring circular array transducers are preferred. However, these are custom built, very expensive, and not available readily on the market, whereas SUTs are cheap and easily available. Thus, PACT systems can be made cost effective by using SUTs. To improve the data acquisition speed, multiple SUTs can be employed at the same time. This will reduce the acquisition time by N-fold if N numbers of SUTs are used, each rotating 360/N degrees. Experimentally, all SUTs cannot be placed exactly at the same distance from the scanning center. Hence, the acquired PA data from each transducer need to be reconstructed with their corresponding radii in a delay-and-sum reconstruction algorithm. This requires the exact location of each SUT from the scanning center. Here, we propose a calibration method to find out the distance from the scanning center at which each SUT acquires the PA data. Three numerical phantoms were used to show the efficacy of the proposed method, and later it was validated with experimental data (point source phantom). National Medical Research Council (NMRC) National Research Foundation (NRF) Accepted version Singapore National Research Foundation administered by the Singapore Ministry of Health’s National Medical Research Council (NMRC/OFIRG/0005/2016: M4062012). Authors have no relevant financial interests in the manuscript and no other potential conflicts of interest to disclose. 2018-04-20T08:19:37Z 2019-12-06T17:07:11Z 2018-04-20T08:19:37Z 2019-12-06T17:07:11Z 2018 2018 Journal Article Kalva, S. K., Hui, Z. Z., & Pramanik, M. (2018). Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system. Journal of the Optical Society of America A, 35(5), 764-771. 1084-7529 https://hdl.handle.net/10356/88609 http://hdl.handle.net/10220/44706 10.1364/JOSAA.35.000764 206050 206050 206050 en Journal of the Optical Society of America A © 2018 Optical Society of America (OSA). This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of the Optical Society of America A, Optical Society of America (OSA). It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1364/JOSAA.35.000764]. 8 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Image Reconstruction Techniques
Photoacoustic Imaging
spellingShingle Image Reconstruction Techniques
Photoacoustic Imaging
Kalva, Sandeep Kumar
Hui, Zhe Zhi
Pramanik, Manojit
Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
description In a circular scanning photoacoustic computed tomography (PAT/PACT) system, a single-element ultrasound transducer (SUT) (rotates in full 360° around the sample) or a full-ring array transducer is used to acquire the photoacoustic (PA) data from the target object. SUT takes several minutes to acquire the PA data, whereas the full-ring array transducer takes only few seconds. Hence, for real-time imaging, full-ring circular array transducers are preferred. However, these are custom built, very expensive, and not available readily on the market, whereas SUTs are cheap and easily available. Thus, PACT systems can be made cost effective by using SUTs. To improve the data acquisition speed, multiple SUTs can be employed at the same time. This will reduce the acquisition time by N-fold if N numbers of SUTs are used, each rotating 360/N degrees. Experimentally, all SUTs cannot be placed exactly at the same distance from the scanning center. Hence, the acquired PA data from each transducer need to be reconstructed with their corresponding radii in a delay-and-sum reconstruction algorithm. This requires the exact location of each SUT from the scanning center. Here, we propose a calibration method to find out the distance from the scanning center at which each SUT acquires the PA data. Three numerical phantoms were used to show the efficacy of the proposed method, and later it was validated with experimental data (point source phantom).
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Kalva, Sandeep Kumar
Hui, Zhe Zhi
Pramanik, Manojit
format Article
author Kalva, Sandeep Kumar
Hui, Zhe Zhi
Pramanik, Manojit
author_sort Kalva, Sandeep Kumar
title Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
title_short Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
title_full Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
title_fullStr Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
title_full_unstemmed Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
title_sort calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system
publishDate 2018
url https://hdl.handle.net/10356/88609
http://hdl.handle.net/10220/44706
_version_ 1787136774501302272