Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture

Modularity and high reliability from redundancy are the two attractive advantages of modular multilevel converters (MMCs). This paper elaborates a switch open-circuit fault diagnosis and a fault-tolerant operation scheme for MMCs with distributed control. The proposed fault diagnosis and fault-toler...

全面介紹

Saved in:
書目詳細資料
Main Authors: Yang, Shunfeng, Tang, Yi, Wang, Peng
其他作者: School of Electrical and Electronic Engineering
格式: Article
語言:English
出版: 2019
主題:
在線閱讀:https://hdl.handle.net/10356/90256
http://hdl.handle.net/10220/48459
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Nanyang Technological University
語言: English
id sg-ntu-dr.10356-90256
record_format dspace
spelling sg-ntu-dr.10356-902562020-03-07T14:02:39Z Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture Yang, Shunfeng Tang, Yi Wang, Peng School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering Distributed Control Fault Diagnosis Modularity and high reliability from redundancy are the two attractive advantages of modular multilevel converters (MMCs). This paper elaborates a switch open-circuit fault diagnosis and a fault-tolerant operation scheme for MMCs with distributed control. The proposed fault diagnosis and fault-tolerant control method can significantly improve the reliability of the MMC while maintaining the modularity of its software implementation. By distributing fault diagnosis into submodules, its local controller is capable of identifying the switching devices in open-circuit fault without extra hardware circuitry. Based on the real-time measurements of submodule terminal voltage and arm current, single, or multiple faulty switches can be identified within 3.5 ms without triggering faulty alarms. Furthermore, a new fault-tolerant operation is proposed to maintain the output current, internal dynamics, and switching harmonics unchanged after the faulty submodule is bypassed. This is achieved by resetting the period and phase registers in the local controller according to the information of bypassed submodules. The control loops of the MMC are not influenced by the proposed fault diagnosis and fault-tolerant operation, making the operation transition seamless and reliable. Experimental results show that fault identification and system reconfiguration can be completed within 5 ms, and the MMC can seamlessly and smooth ride through the switch open-circuit faults without severe malfunction and catastrophic damages. NRF (Natl Research Foundation, S’pore) Accepted version 2019-05-29T08:31:25Z 2019-12-06T17:44:10Z 2019-05-29T08:31:25Z 2019-12-06T17:44:10Z 2017 Journal Article Yang, S., Tang, Y., & Wang, P. (2018). Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture. IEEE Transactions on Power Electronics, 33(8), 7058-7070. doi:10.1109/TPEL.2017.2756849 0885-8993 https://hdl.handle.net/10356/90256 http://hdl.handle.net/10220/48459 10.1109/TPEL.2017.2756849 en IEEE Transactions on Power Electronics © 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: https://doi.org/10.1109/TPEL.2017.2756849 12 p. application/pdf
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
Distributed Control
Fault Diagnosis
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Distributed Control
Fault Diagnosis
Yang, Shunfeng
Tang, Yi
Wang, Peng
Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
description Modularity and high reliability from redundancy are the two attractive advantages of modular multilevel converters (MMCs). This paper elaborates a switch open-circuit fault diagnosis and a fault-tolerant operation scheme for MMCs with distributed control. The proposed fault diagnosis and fault-tolerant control method can significantly improve the reliability of the MMC while maintaining the modularity of its software implementation. By distributing fault diagnosis into submodules, its local controller is capable of identifying the switching devices in open-circuit fault without extra hardware circuitry. Based on the real-time measurements of submodule terminal voltage and arm current, single, or multiple faulty switches can be identified within 3.5 ms without triggering faulty alarms. Furthermore, a new fault-tolerant operation is proposed to maintain the output current, internal dynamics, and switching harmonics unchanged after the faulty submodule is bypassed. This is achieved by resetting the period and phase registers in the local controller according to the information of bypassed submodules. The control loops of the MMC are not influenced by the proposed fault diagnosis and fault-tolerant operation, making the operation transition seamless and reliable. Experimental results show that fault identification and system reconfiguration can be completed within 5 ms, and the MMC can seamlessly and smooth ride through the switch open-circuit faults without severe malfunction and catastrophic damages.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Yang, Shunfeng
Tang, Yi
Wang, Peng
format Article
author Yang, Shunfeng
Tang, Yi
Wang, Peng
author_sort Yang, Shunfeng
title Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
title_short Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
title_full Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
title_fullStr Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
title_full_unstemmed Seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
title_sort seamless fault-tolerant operation of a modular multilevel converter with switch open-circuit fault diagnosis in a distributed control architecture
publishDate 2019
url https://hdl.handle.net/10356/90256
http://hdl.handle.net/10220/48459
_version_ 1681045644017401856