Time-variant in-circuit impedance monitoring based on the inductive coupling method

In-circuit impedance extraction of a time-variant electrical system is essential for real-time condition monitoring purpose. This paper looks into the design consideration of real-time in-circuit monitoring for a time-variant system based on inductive coupling approach and discrete Fourier transform...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhao, Zhenyu, See, Kye-Yak, Chua, Eng-Kee, Narayanan, Arun Shankar, Chen, Wayne, Weerasinghe, Arjuna
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2019
Subjects:
Online Access:https://hdl.handle.net/10356/90257
http://hdl.handle.net/10220/48458
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
Description
Summary:In-circuit impedance extraction of a time-variant electrical system is essential for real-time condition monitoring purpose. This paper looks into the design consideration of real-time in-circuit monitoring for a time-variant system based on inductive coupling approach and discrete Fourier transform in a moving window. By using two clamped-on-type inductive probes, the proposed setup eliminates the need of voltage sensors to measure the terminal voltages of system-under-monitoring (SUM) and, hence, eliminates direct electrical contact with the SUM. Therefore, it facilitates ease of mounting and disassembly. Experimental results show that with careful design consideration, the proposed method has the ability to measure the in-circuit impedance of a time-variant system in real time, which facilitates useful inputs for early detection of abnormality of the monitored electrical system that is time variant in nature.