Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system

A special structure thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-condition system was designed and experimentally measured on its elevating effects. Under the determinate operation conditions, its transient state performances were tested. The curves o...

Full description

Saved in:
Bibliographic Details
Main Authors: Li, Zhengliang, Zhang, Xiang, Zheng, Hongfei, Wang, Daxi
Other Authors: School of Materials Science & Engineering
Format: Article
Language:English
Published: 2011
Subjects:
Online Access:https://hdl.handle.net/10356/91424
http://hdl.handle.net/10220/7027
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-91424
record_format dspace
spelling sg-ntu-dr.10356-914242023-07-14T15:53:03Z Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system Li, Zhengliang Zhang, Xiang Zheng, Hongfei Wang, Daxi School of Materials Science & Engineering DRNTU::Engineering::Mechanical engineering::Alternative, renewable energy sources A special structure thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-condition system was designed and experimentally measured on its elevating effects. Under the determinate operation conditions, its transient state performances were tested. The curves of the temperature and strong solution elevation volume with operating time were given out. Researches indicate that only 20 minutes is required from start-up to steady operation. Under the steady state conditions, the elevating rate of the strong solution and the distilled water yield rate versus the operating temperature were investigated. The minimum start-up operating temperature under different the immersing heights and the weak solution concentration were determined. The experimental results show that under the operating temperature condition of 85 °C, the strong solution elevation rate could reach 32 ml/s for 45% weak solution concentration. If all distilled water is evaporated, the refrigeration capability of the chiller can reach about 9 kW. At the same time, the heat transfer density of the lunate channel wall is about 10.2 kW/m2. Accepted version 2011-09-08T08:26:25Z 2019-12-06T18:05:27Z 2011-09-08T08:26:25Z 2019-12-06T18:05:27Z 2009 2009 Journal Article Li, Z., Zhang, X., Zheng, H., & Wang, D. (2009). Experimental Study on the Thermosiphon Solution Elevation Pump With Multiple Lunate Channels Used in Minitype Solar Air-Conditionding System. Proceedings of ISES Solar World Congress 2007: Solar Energy and Human Settlement,3, 912-915. https://hdl.handle.net/10356/91424 http://hdl.handle.net/10220/7027 10.1007/978-3-540-75997-3_175 155463 en Proceedings of ISES solar world congress 2007. solar energy and human settlement © 2009 Springer. This is the author created version of a work that has been peer reviewed and accepted for publication by Proceedings of ISES Solar World Congress 2007: Solar Energy and Human Settlement, Springer. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1007/978-3-540-75997-3_175]. 4 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Alternative, renewable energy sources
spellingShingle DRNTU::Engineering::Mechanical engineering::Alternative, renewable energy sources
Li, Zhengliang
Zhang, Xiang
Zheng, Hongfei
Wang, Daxi
Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
description A special structure thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-condition system was designed and experimentally measured on its elevating effects. Under the determinate operation conditions, its transient state performances were tested. The curves of the temperature and strong solution elevation volume with operating time were given out. Researches indicate that only 20 minutes is required from start-up to steady operation. Under the steady state conditions, the elevating rate of the strong solution and the distilled water yield rate versus the operating temperature were investigated. The minimum start-up operating temperature under different the immersing heights and the weak solution concentration were determined. The experimental results show that under the operating temperature condition of 85 °C, the strong solution elevation rate could reach 32 ml/s for 45% weak solution concentration. If all distilled water is evaporated, the refrigeration capability of the chiller can reach about 9 kW. At the same time, the heat transfer density of the lunate channel wall is about 10.2 kW/m2.
author2 School of Materials Science & Engineering
author_facet School of Materials Science & Engineering
Li, Zhengliang
Zhang, Xiang
Zheng, Hongfei
Wang, Daxi
format Article
author Li, Zhengliang
Zhang, Xiang
Zheng, Hongfei
Wang, Daxi
author_sort Li, Zhengliang
title Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
title_short Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
title_full Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
title_fullStr Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
title_full_unstemmed Experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
title_sort experimental study on the thermosiphon solution elevation pump with multiple lunate channels used in minitype solar air-conditionding system
publishDate 2011
url https://hdl.handle.net/10356/91424
http://hdl.handle.net/10220/7027
_version_ 1772827918913765376