Assessment of EMI chokes under realistic loading conditions

A novel measurement method has been developed to characterize the common-mode (CM) and differential-mode (DM) impedances of power line EMI chokes under realistic loading conditions. With a proper pre-measurement calibration process, all parasitic effects in the measurement setup can be eliminated. T...