Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node

Delay-and-sum (DAS) is one of the most common algorithms used to construct the photoacoustic images due to its low complexity. However, it results in images with high sidelobes and low resolution. Delay-and-standard-deviation (DASD) weighting factor can improve the contrast of the images compared to...

全面介紹

Saved in:
書目詳細資料
Main Authors: Paridar, Roya, Pramanik, Manojit, Orooji, Mahdi, Periyasamy, Vijitha, Mehrmohammadi, Mohammad, Mozaffarzadeh, Moein, Basij, Maryam
其他作者: School of Chemical and Biomedical Engineering
格式: Article
語言:English
出版: 2019
主題:
在線閱讀:https://hdl.handle.net/10356/93621
http://hdl.handle.net/10220/48756
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Nanyang Technological University
語言: English
id sg-ntu-dr.10356-93621
record_format dspace
spelling sg-ntu-dr.10356-936212023-12-29T06:53:28Z Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node Paridar, Roya Pramanik, Manojit Orooji, Mahdi Periyasamy, Vijitha Mehrmohammadi, Mohammad Mozaffarzadeh, Moein Basij, Maryam School of Chemical and Biomedical Engineering Image Reconstruction DRNTU::Engineering::Chemical engineering Noise Suppression Delay-and-sum (DAS) is one of the most common algorithms used to construct the photoacoustic images due to its low complexity. However, it results in images with high sidelobes and low resolution. Delay-and-standard-deviation (DASD) weighting factor can improve the contrast of the images compared to DAS. However, it still suffers from high sidelobes. In this work, a new weighting factor, named delay-multiply-and-standard-deviation (DMASD) is introduced to enhance the contrast of the reconstructed images compared to other mentioned methods. In the proposed method, the standard deviation of the mutual multiplied delayed signals are calculated, normalized and multiplied to DAS beamformed data. The results show that DMASD improves the signal-to-noise-ratio about 19.29 dB and 7.3 dB compared to DAS and DASD, respectively, for in vivo imaging of the sentinel lymph node. Moreover, the contrast-ratio is improve by the DMASD about 23.61 dB and 10.81 dB compared to DAS and DASD, respectively. Accepted version 2019-06-14T04:36:55Z 2019-12-06T18:42:29Z 2019-06-14T04:36:55Z 2019-12-06T18:42:29Z 2019 2018 Journal Article Paridar, R., Mozaffarzadeh, M., Periyasamy, V., Basij, M., Mehrmohammadi, M., Pramanik, M., & Orooji, M. (2019). Validation of delay‐multiply‐and‐standard‐deviation weighting factor for improved photoacoustic imaging of sentinel lymph node. Journal of Biophotonics, 12(6), e201800292-. doi:10.1002/jbio.201800292 1864-063X https://hdl.handle.net/10356/93621 http://hdl.handle.net/10220/48756 10.1002/jbio.201800292 214591 en Journal of Biophotonics This is the peer reviewed version of the following article: Paridar, R., Mozaffarzadeh, M., Periyasamy, V., Basij, M., Mehrmohammadi, M., Pramanik, M., & Orooji, M. (2019). Validation of delay‐multiply‐and‐standard‐deviation weighting factor for improved photoacoustic imaging of sentinel lymph node. Journal of Biophotonics, 12(6), e201800292-. doi:10.1002/jbio.201800292, which has been published in final form at http://dx.doi.org/10.1002/jbio.201800292. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. 9 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Image Reconstruction
DRNTU::Engineering::Chemical engineering
Noise Suppression
spellingShingle Image Reconstruction
DRNTU::Engineering::Chemical engineering
Noise Suppression
Paridar, Roya
Pramanik, Manojit
Orooji, Mahdi
Periyasamy, Vijitha
Mehrmohammadi, Mohammad
Mozaffarzadeh, Moein
Basij, Maryam
Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
description Delay-and-sum (DAS) is one of the most common algorithms used to construct the photoacoustic images due to its low complexity. However, it results in images with high sidelobes and low resolution. Delay-and-standard-deviation (DASD) weighting factor can improve the contrast of the images compared to DAS. However, it still suffers from high sidelobes. In this work, a new weighting factor, named delay-multiply-and-standard-deviation (DMASD) is introduced to enhance the contrast of the reconstructed images compared to other mentioned methods. In the proposed method, the standard deviation of the mutual multiplied delayed signals are calculated, normalized and multiplied to DAS beamformed data. The results show that DMASD improves the signal-to-noise-ratio about 19.29 dB and 7.3 dB compared to DAS and DASD, respectively, for in vivo imaging of the sentinel lymph node. Moreover, the contrast-ratio is improve by the DMASD about 23.61 dB and 10.81 dB compared to DAS and DASD, respectively.
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Paridar, Roya
Pramanik, Manojit
Orooji, Mahdi
Periyasamy, Vijitha
Mehrmohammadi, Mohammad
Mozaffarzadeh, Moein
Basij, Maryam
format Article
author Paridar, Roya
Pramanik, Manojit
Orooji, Mahdi
Periyasamy, Vijitha
Mehrmohammadi, Mohammad
Mozaffarzadeh, Moein
Basij, Maryam
author_sort Paridar, Roya
title Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
title_short Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
title_full Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
title_fullStr Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
title_full_unstemmed Validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
title_sort validation of delay-multiply-and-standard-deviation weighting factor for improved photoacoustic imaging of sentinel lymph node
publishDate 2019
url https://hdl.handle.net/10356/93621
http://hdl.handle.net/10220/48756
_version_ 1787136797507059712