Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode
Appropriately designing and maintaining temperature and relative humidity in a given space is essential for active chilled beam systems, where condensation should be strictly prevented. As a consequence, the Total Cooling Output Capacity (TCOC) of an active chilled beam system should be matched with...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/96290 http://hdl.handle.net/10220/38484 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-96290 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-962902020-03-07T14:02:44Z Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode Chen, Can Cai, Wenjian Wang, Youyi Lin, Chen Wang, Lei School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Power electronics Appropriately designing and maintaining temperature and relative humidity in a given space is essential for active chilled beam systems, where condensation should be strictly prevented. As a consequence, the Total Cooling Output Capacity (TCOC) of an active chilled beam system should be matched with the total cooling load of the applied space, as well as the Sensible Heat Ratio (SHR) of the system with the SHR of the space. From such a perspective, this paper for the first time explored the operating characteristics of a 2-way discharge active chilled beam terminal unit. Based on an experimentally verified model of the unit, a series of realistic simulations were carried out under various primary air volume flow rates and various chilled water volume flow rates. Inherent correlations between the TCOC and SHR were revealed. In the meanwhile, the operating efficiencies of the unit were also measured by an energy saving potential index ɛ, which is defined as the ratio of chilled water sensible cooling output capacity to the total sensible cooling output capacity. In addition, influences of different primary air and space conditions on the operating characteristics and efficiencies were studied. The results obtained in this study are expected to facilitate a better understanding of the active chilled beam terminal unit, so as to the designs, the operating principles, and the control strategies of active chilled beam systems for an improved indoor thermal environment. Accepted version 2015-08-21T02:07:01Z 2019-12-06T19:28:15Z 2015-08-21T02:07:01Z 2019-12-06T19:28:15Z 2015 2015 Journal Article Chen, C., Cai, W., Wang, Y., Lin, C., & Wang, L. (2015). Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode. Applied Thermal Engineering, 85, 71-79. 1359-4311 https://hdl.handle.net/10356/96290 http://hdl.handle.net/10220/38484 10.1016/j.applthermaleng.2015.03.016 en Applied thermal engineering © 2015 Elsevier Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Applied Thermal Engineering, Elsevier Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.applthermaleng.2015.03.016]. 18 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Electrical and electronic engineering::Power electronics |
spellingShingle |
DRNTU::Engineering::Electrical and electronic engineering::Power electronics Chen, Can Cai, Wenjian Wang, Youyi Lin, Chen Wang, Lei Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
description |
Appropriately designing and maintaining temperature and relative humidity in a given space is essential for active chilled beam systems, where condensation should be strictly prevented. As a consequence, the Total Cooling Output Capacity (TCOC) of an active chilled beam system should be matched with the total cooling load of the applied space, as well as the Sensible Heat Ratio (SHR) of the system with the SHR of the space. From such a perspective, this paper for the first time explored the operating characteristics of a 2-way discharge active chilled beam terminal unit. Based on an experimentally verified model of the unit, a series of realistic simulations were carried out under various primary air volume flow rates and various chilled water volume flow rates. Inherent correlations between the TCOC and SHR were revealed. In the meanwhile, the operating efficiencies of the unit were also measured by an energy saving potential index ɛ, which is defined as the ratio of chilled water sensible cooling output capacity to the total sensible cooling output capacity. In addition, influences of different primary air and space conditions on the operating characteristics and efficiencies were studied. The results obtained in this study are expected to facilitate a better understanding of the active chilled beam terminal unit, so as to the designs, the operating principles, and the control strategies of active chilled beam systems for an improved indoor thermal environment. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Chen, Can Cai, Wenjian Wang, Youyi Lin, Chen Wang, Lei |
format |
Article |
author |
Chen, Can Cai, Wenjian Wang, Youyi Lin, Chen Wang, Lei |
author_sort |
Chen, Can |
title |
Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
title_short |
Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
title_full |
Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
title_fullStr |
Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
title_full_unstemmed |
Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
title_sort |
operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode |
publishDate |
2015 |
url |
https://hdl.handle.net/10356/96290 http://hdl.handle.net/10220/38484 |
_version_ |
1681038267809529856 |