Effect of unprotected interior beams on membrane behaviour of composite floor systems in fire, I : experimental investigation

A number of previous studies on tensile membrane action have been conducted and they are very valuable towards understanding the behaviour of isolated slabs as well as of floor assemblies. However, the role of unprotected interior beams in the development of TMA still has not clearly determined. Th...

Full description

Saved in:
Bibliographic Details
Main Authors: Tan, Kang Hai, Nguyen, Tuan Trung
Other Authors: School of Civil and Environmental Engineering
Format: Conference or Workshop Item
Language:English
Published: 2013
Online Access:https://hdl.handle.net/10356/96898
http://hdl.handle.net/10220/10657
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
Description
Summary:A number of previous studies on tensile membrane action have been conducted and they are very valuable towards understanding the behaviour of isolated slabs as well as of floor assemblies. However, the role of unprotected interior beams in the development of TMA still has not clearly determined. This paper presents an experimental study on the effect of unprotected interior beams on the behaviour of composite floor assemblies in fire. The experimental observations and results of two one-fourth scale composite slab-beam systems, 3.15 m by 3.15 m in plan, subjected to transient-heating test are presented. The test results show that the presence of interior beams can reduce the slab deflection and greatly enhance the slab load-bearing capacity. The interior beams have a major role in helping the slab in passing through the ‘transition’ stage, and thus the slab can mobilize more tensile membrane forces. Without the interior beams, the compressive ring failure may occur resulting in a little contribution from TMA in the slab load-bearing capacity.