Impedimetric thrombin aptasensor based on chemically modified graphenes
Highly sensitive biosensors are of high importance to the biomedical field. Graphene represents a promising transducing platform for construction of biosensors. Here for the first time we compare the biosensing performance of a wide set of graphenes prepared by different methods. In this work, we pr...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2013
|
Online Access: | https://hdl.handle.net/10356/97509 http://hdl.handle.net/10220/10683 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-97509 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-975092020-03-07T12:34:44Z Impedimetric thrombin aptasensor based on chemically modified graphenes Loo, Adeline Huiling Bonanni, Alessandra Pumera, Martin School of Physical and Mathematical Sciences Highly sensitive biosensors are of high importance to the biomedical field. Graphene represents a promising transducing platform for construction of biosensors. Here for the first time we compare the biosensing performance of a wide set of graphenes prepared by different methods. In this work, we present a simple and label-free electrochemical impedimetric aptasensor for thrombin based on chemically modified graphene (CMG) platforms such as graphite oxide (GPO), graphene oxide (GO), thermally reduced graphene oxide (TR-GO) and electrochemically reduced graphene oxide (ER-GO). Disposable screen-printed electrodes were first modified with chemically modified graphene (CMG) materials and used to immobilize a DNA aptamer which is specific to thrombin. The basis of detection relies on the changes in impedance spectra of redox probe after the binding of thrombin to the aptamer. It was discovered that graphene oxide (GO) is the most suitable material to be used as compared to the other three CMG materials. Furthermore, the optimum concentration of aptamer to be immobilized onto the modified electrode surface was determined to be 10 μM and the linear detection range of thrombin was 10–50 nM. Lastly, the aptasensor was found to demonstrate selectivity for thrombin. Such simply fabricated graphene oxide aptasensor shows high promise for clinical diagnosis of biomarkers and point-of-care analysis. 2013-06-26T02:11:02Z 2019-12-06T19:43:26Z 2013-06-26T02:11:02Z 2019-12-06T19:43:26Z 2012 2012 Journal Article Loo, A. H., Bonanni, A., & Pumera, M. (2011). Impedimetric thrombin aptasensor based on chemically modified graphenes. Nanoscale, 4(1), 143-147. 2040-3364 https://hdl.handle.net/10356/97509 http://hdl.handle.net/10220/10683 10.1039/c1nr10966a en Nanoscale © 2012 The Royal Society of Chemistry. |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
description |
Highly sensitive biosensors are of high importance to the biomedical field. Graphene represents a promising transducing platform for construction of biosensors. Here for the first time we compare the biosensing performance of a wide set of graphenes prepared by different methods. In this work, we present a simple and label-free electrochemical impedimetric aptasensor for thrombin based on chemically modified graphene (CMG) platforms such as graphite oxide (GPO), graphene oxide (GO), thermally reduced graphene oxide (TR-GO) and electrochemically reduced graphene oxide (ER-GO). Disposable screen-printed electrodes were first modified with chemically modified graphene (CMG) materials and used to immobilize a DNA aptamer which is specific to thrombin. The basis of detection relies on the changes in impedance spectra of redox probe after the binding of thrombin to the aptamer. It was discovered that graphene oxide (GO) is the most suitable material to be used as compared to the other three CMG materials. Furthermore, the optimum concentration of aptamer to be immobilized onto the modified electrode surface was determined to be 10 μM and the linear detection range of thrombin was 10–50 nM. Lastly, the aptasensor was found to demonstrate selectivity for thrombin. Such simply fabricated graphene oxide aptasensor shows high promise for clinical diagnosis of biomarkers and point-of-care analysis. |
author2 |
School of Physical and Mathematical Sciences |
author_facet |
School of Physical and Mathematical Sciences Loo, Adeline Huiling Bonanni, Alessandra Pumera, Martin |
format |
Article |
author |
Loo, Adeline Huiling Bonanni, Alessandra Pumera, Martin |
spellingShingle |
Loo, Adeline Huiling Bonanni, Alessandra Pumera, Martin Impedimetric thrombin aptasensor based on chemically modified graphenes |
author_sort |
Loo, Adeline Huiling |
title |
Impedimetric thrombin aptasensor based on chemically modified graphenes |
title_short |
Impedimetric thrombin aptasensor based on chemically modified graphenes |
title_full |
Impedimetric thrombin aptasensor based on chemically modified graphenes |
title_fullStr |
Impedimetric thrombin aptasensor based on chemically modified graphenes |
title_full_unstemmed |
Impedimetric thrombin aptasensor based on chemically modified graphenes |
title_sort |
impedimetric thrombin aptasensor based on chemically modified graphenes |
publishDate |
2013 |
url |
https://hdl.handle.net/10356/97509 http://hdl.handle.net/10220/10683 |
_version_ |
1681034711417225216 |