Fire resistance for square tubular joints with and without chord reinforcement
The chord surface around the brace/chord weld toe for a square welded tubular joint is the critical position because failure occurs frequently at this location due to the weak stiffness in the transverse direction of the chord which is generally a thin-walled tube. To improve the load carrying capac...
Saved in:
Main Authors: | Yang, J., Shao, Y. B., Cheng, C., Lie, S. T., Chiew, Sing Ping |
---|---|
Other Authors: | School of Civil and Environmental Engineering |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2013
|
Online Access: | https://hdl.handle.net/10356/98779 http://hdl.handle.net/10220/13420 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Similar Items
-
Hysteretic behaviour of square tubular T-joints with chord reinforcement under axial cyclic loading
by: Shao, Yong-Bo, et al.
Published: (2014) -
Stress intensity factor for a tubular T-joint with grouted chord
by: Shen, W., et al.
Published: (2014) -
Recent research on tubular joints with very thick-walled chords
by: Choo, Y.S., et al.
Published: (2014) -
Research on tubular joints at Nanyang Technological University
by: Lie, S. T., et al.
Published: (2014) -
Static Strength of Tubular X-joints with Chord Fully Infilled with High Strength Grout.
by: CHEN ZHUO
Published: (2011)