A 0.18μm front end for ECG/EEG/neural sensor interface
A 1.8V 0.18μm CMOS analog front end consists of a chopper stabilized low noise preamplifier, a capacitive negative feedback gain stage and a variable gain amplifier with digital tunable low pass filter bank is presented. With optimized gain distribution, the analog front end eliminates the 1/f noise...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2013
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/99012 http://hdl.handle.net/10220/12756 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-99012 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-990122020-03-07T13:24:49Z A 0.18μm front end for ECG/EEG/neural sensor interface Han, Dong Zheng, Yuanjin Je, Minkyu School of Electrical and Electronic Engineering IEEE International Symposium on Radio-Frequency Integration Technology (2012 : Singapore) DRNTU::Engineering::Electrical and electronic engineering A 1.8V 0.18μm CMOS analog front end consists of a chopper stabilized low noise preamplifier, a capacitive negative feedback gain stage and a variable gain amplifier with digital tunable low pass filter bank is presented. With optimized gain distribution, the analog front end eliminates the 1/f noise by chopper stabilization without the DC offset cancellation servo loops in conventional chopper amplifier, combines the advantages from chopper stabilization and capacitive negative feedback to achieve both low 1/f noise and compact structure. The simulation results show that the proposed analog front end achieves 32nV/Hz1/2 input referred thermal noise floor with 1.8μA total current from a 1.8V supply, 20kHz chopping frequency, and in-band gain of 400 and 2000, is suitable for electrocardiograph, electroencephalograph, and neural spike recording applications. 2013-08-01T03:53:53Z 2019-12-06T20:02:19Z 2013-08-01T03:53:53Z 2019-12-06T20:02:19Z 2012 2012 Conference Paper Han, D., Zheng, Y.,& Je, M. (2012). A 0.18μm front end for ECG/EEG/neural sensor interface. 2012 IEEE International Symposium on Radio-Frequency Integration Technology (RFIT),107-109. https://hdl.handle.net/10356/99012 http://hdl.handle.net/10220/12756 10.1109/RFIT.2012.6401629 en |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Electrical and electronic engineering |
spellingShingle |
DRNTU::Engineering::Electrical and electronic engineering Han, Dong Zheng, Yuanjin Je, Minkyu A 0.18μm front end for ECG/EEG/neural sensor interface |
description |
A 1.8V 0.18μm CMOS analog front end consists of a chopper stabilized low noise preamplifier, a capacitive negative feedback gain stage and a variable gain amplifier with digital tunable low pass filter bank is presented. With optimized gain distribution, the analog front end eliminates the 1/f noise by chopper stabilization without the DC offset cancellation servo loops in conventional chopper amplifier, combines the advantages from chopper stabilization and capacitive negative feedback to achieve both low 1/f noise and compact structure. The simulation results show that the proposed analog front end achieves 32nV/Hz1/2 input referred thermal noise floor with 1.8μA total current from a 1.8V supply, 20kHz chopping frequency, and in-band gain of 400 and 2000, is suitable for electrocardiograph, electroencephalograph, and neural spike recording applications. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Han, Dong Zheng, Yuanjin Je, Minkyu |
format |
Conference or Workshop Item |
author |
Han, Dong Zheng, Yuanjin Je, Minkyu |
author_sort |
Han, Dong |
title |
A 0.18μm front end for ECG/EEG/neural sensor interface |
title_short |
A 0.18μm front end for ECG/EEG/neural sensor interface |
title_full |
A 0.18μm front end for ECG/EEG/neural sensor interface |
title_fullStr |
A 0.18μm front end for ECG/EEG/neural sensor interface |
title_full_unstemmed |
A 0.18μm front end for ECG/EEG/neural sensor interface |
title_sort |
0.18μm front end for ecg/eeg/neural sensor interface |
publishDate |
2013 |
url |
https://hdl.handle.net/10356/99012 http://hdl.handle.net/10220/12756 |
_version_ |
1681036777491529728 |