A 0.18μm front end for ECG/EEG/neural sensor interface

A 1.8V 0.18μm CMOS analog front end consists of a chopper stabilized low noise preamplifier, a capacitive negative feedback gain stage and a variable gain amplifier with digital tunable low pass filter bank is presented. With optimized gain distribution, the analog front end eliminates the 1/f noise...

Full description

Saved in:
Bibliographic Details
Main Authors: Han, Dong, Zheng, Yuanjin, Je, Minkyu
Other Authors: School of Electrical and Electronic Engineering
Format: Conference or Workshop Item
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/99012
http://hdl.handle.net/10220/12756
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-99012
record_format dspace
spelling sg-ntu-dr.10356-990122020-03-07T13:24:49Z A 0.18μm front end for ECG/EEG/neural sensor interface Han, Dong Zheng, Yuanjin Je, Minkyu School of Electrical and Electronic Engineering IEEE International Symposium on Radio-Frequency Integration Technology (2012 : Singapore) DRNTU::Engineering::Electrical and electronic engineering A 1.8V 0.18μm CMOS analog front end consists of a chopper stabilized low noise preamplifier, a capacitive negative feedback gain stage and a variable gain amplifier with digital tunable low pass filter bank is presented. With optimized gain distribution, the analog front end eliminates the 1/f noise by chopper stabilization without the DC offset cancellation servo loops in conventional chopper amplifier, combines the advantages from chopper stabilization and capacitive negative feedback to achieve both low 1/f noise and compact structure. The simulation results show that the proposed analog front end achieves 32nV/Hz1/2 input referred thermal noise floor with 1.8μA total current from a 1.8V supply, 20kHz chopping frequency, and in-band gain of 400 and 2000, is suitable for electrocardiograph, electroencephalograph, and neural spike recording applications. 2013-08-01T03:53:53Z 2019-12-06T20:02:19Z 2013-08-01T03:53:53Z 2019-12-06T20:02:19Z 2012 2012 Conference Paper Han, D., Zheng, Y.,& Je, M. (2012). A 0.18μm front end for ECG/EEG/neural sensor interface. 2012 IEEE International Symposium on Radio-Frequency Integration Technology (RFIT),107-109. https://hdl.handle.net/10356/99012 http://hdl.handle.net/10220/12756 10.1109/RFIT.2012.6401629 en
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Han, Dong
Zheng, Yuanjin
Je, Minkyu
A 0.18μm front end for ECG/EEG/neural sensor interface
description A 1.8V 0.18μm CMOS analog front end consists of a chopper stabilized low noise preamplifier, a capacitive negative feedback gain stage and a variable gain amplifier with digital tunable low pass filter bank is presented. With optimized gain distribution, the analog front end eliminates the 1/f noise by chopper stabilization without the DC offset cancellation servo loops in conventional chopper amplifier, combines the advantages from chopper stabilization and capacitive negative feedback to achieve both low 1/f noise and compact structure. The simulation results show that the proposed analog front end achieves 32nV/Hz1/2 input referred thermal noise floor with 1.8μA total current from a 1.8V supply, 20kHz chopping frequency, and in-band gain of 400 and 2000, is suitable for electrocardiograph, electroencephalograph, and neural spike recording applications.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Han, Dong
Zheng, Yuanjin
Je, Minkyu
format Conference or Workshop Item
author Han, Dong
Zheng, Yuanjin
Je, Minkyu
author_sort Han, Dong
title A 0.18μm front end for ECG/EEG/neural sensor interface
title_short A 0.18μm front end for ECG/EEG/neural sensor interface
title_full A 0.18μm front end for ECG/EEG/neural sensor interface
title_fullStr A 0.18μm front end for ECG/EEG/neural sensor interface
title_full_unstemmed A 0.18μm front end for ECG/EEG/neural sensor interface
title_sort 0.18μm front end for ecg/eeg/neural sensor interface
publishDate 2013
url https://hdl.handle.net/10356/99012
http://hdl.handle.net/10220/12756
_version_ 1681036777491529728