Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
An evaluation methodology of the electromagnetic interference (EMI) suppression performance of a ferrite core clamped onto a power cord under its actual operating condition is proposed. With known electrical parameters of a ferrite core, the true EMI suppression performance of the ferrite core at a...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2013
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/99400 http://hdl.handle.net/10220/17783 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-99400 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-994002020-03-07T14:02:44Z Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord Zhao, Y. Hu, B. See, Kye Yak Tarateeraseth, Vuttipon School of Electrical and Electronic Engineering School of Electrical and Automation Engineering, Nanjing Normal University Dipartimento di Elettronica, Politecnico di Torino, Italy DRNTU::Engineering::Electrical and electronic engineering An evaluation methodology of the electromagnetic interference (EMI) suppression performance of a ferrite core clamped onto a power cord under its actual operating condition is proposed. With known electrical parameters of a ferrite core, the true EMI suppression performance of the ferrite core at a specific location on a power cord under its intended operating condition can be determined. Based on a two-probe inductive coupling approach, the current probes are clamped on the power cord and the EMI attenuation of a ferrite core loaded power cord can be assessed more objectively without the actual operation interrupted. Taking into account the common-mode impedance of the ferrite core and the common-mode impedances of the power cord terminated with the intended source and load, the true EMI suppression performance of the ferrite core located at different positions along the power cord can be evaluated with confidence. The measured EMI suppression has also been validated with the simulation results using the transmission line model 2013-11-19T05:13:12Z 2019-12-06T20:06:48Z 2013-11-19T05:13:12Z 2019-12-06T20:06:48Z 2010 2010 Journal Article Hu, B., Tarateeraseth, V., See, K. Y., & Zhao, Y. (2010). Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord. IET Science, Measurement & Technology, 4(4), 229-236. https://hdl.handle.net/10356/99400 http://hdl.handle.net/10220/17783 10.1049/iet-smt.2009.0120 en IET science, measurement & technology © 2010 The Institution of Engineering and Technology. 8 p. |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Electrical and electronic engineering |
spellingShingle |
DRNTU::Engineering::Electrical and electronic engineering Zhao, Y. Hu, B. See, Kye Yak Tarateeraseth, Vuttipon Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
description |
An evaluation methodology of the electromagnetic interference (EMI) suppression performance of a ferrite core clamped onto a power cord under its actual operating condition is proposed. With known electrical parameters of a ferrite core, the true EMI suppression performance of the ferrite core at a specific location on a power cord under its intended operating condition can be determined. Based on a two-probe inductive coupling approach, the current probes are clamped on the power cord and the EMI attenuation of a
ferrite core loaded power cord can be assessed more objectively without the actual operation interrupted.
Taking into account the common-mode impedance of the ferrite core and the common-mode impedances of
the power cord terminated with the intended source and load, the true EMI suppression performance of the ferrite core located at different positions along the power cord can be evaluated with confidence. The measured EMI suppression has also been validated with the simulation results using the transmission line model |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Zhao, Y. Hu, B. See, Kye Yak Tarateeraseth, Vuttipon |
format |
Article |
author |
Zhao, Y. Hu, B. See, Kye Yak Tarateeraseth, Vuttipon |
author_sort |
Zhao, Y. |
title |
Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
title_short |
Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
title_full |
Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
title_fullStr |
Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
title_full_unstemmed |
Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
title_sort |
assessment of electromagnetic interference suppression performance of ferrite core loaded power cord |
publishDate |
2013 |
url |
https://hdl.handle.net/10356/99400 http://hdl.handle.net/10220/17783 |
_version_ |
1681047109156995072 |