Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients

10.1167/iovs.04-0115

Saved in:
Bibliographic Details
Main Authors: Lam, D.S.C., Leung, D.Y.L., Chiu, T.Y.H., Fan, D.S.P., Cheung, E.Y.Y., Wong, T.-Y., Lai, J.S.M., Tham, C.C.Y.
Other Authors: OPHTHALMOLOGY
Format: Article
Published: 2014
Online Access:http://scholarbank.nus.edu.sg/handle/10635/113597
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: National University of Singapore
id sg-nus-scholar.10635-113597
record_format dspace
spelling sg-nus-scholar.10635-1135972024-11-08T20:21:12Z Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients Lam, D.S.C. Leung, D.Y.L. Chiu, T.Y.H. Fan, D.S.P. Cheung, E.Y.Y. Wong, T.-Y. Lai, J.S.M. Tham, C.C.Y. OPHTHALMOLOGY 10.1167/iovs.04-0115 Investigative Ophthalmology and Visual Science 45 9 3131-3136 IOVSD 2014-12-01T06:56:16Z 2014-12-01T06:56:16Z 2004-09 Article Lam, D.S.C., Leung, D.Y.L., Chiu, T.Y.H., Fan, D.S.P., Cheung, E.Y.Y., Wong, T.-Y., Lai, J.S.M., Tham, C.C.Y. (2004-09). Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients. Investigative Ophthalmology and Visual Science 45 (9) : 3131-3136. ScholarBank@NUS Repository. https://doi.org/10.1167/iovs.04-0115 01460404 http://scholarbank.nus.edu.sg/handle/10635/113597 000223500900036 Scopus
institution National University of Singapore
building NUS Library
continent Asia
country Singapore
Singapore
content_provider NUS Library
collection ScholarBank@NUS
description 10.1167/iovs.04-0115
author2 OPHTHALMOLOGY
author_facet OPHTHALMOLOGY
Lam, D.S.C.
Leung, D.Y.L.
Chiu, T.Y.H.
Fan, D.S.P.
Cheung, E.Y.Y.
Wong, T.-Y.
Lai, J.S.M.
Tham, C.C.Y.
format Article
author Lam, D.S.C.
Leung, D.Y.L.
Chiu, T.Y.H.
Fan, D.S.P.
Cheung, E.Y.Y.
Wong, T.-Y.
Lai, J.S.M.
Tham, C.C.Y.
spellingShingle Lam, D.S.C.
Leung, D.Y.L.
Chiu, T.Y.H.
Fan, D.S.P.
Cheung, E.Y.Y.
Wong, T.-Y.
Lai, J.S.M.
Tham, C.C.Y.
Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
author_sort Lam, D.S.C.
title Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
title_short Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
title_full Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
title_fullStr Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
title_full_unstemmed Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
title_sort pressure phosphene self-tonometry: a comparison with goldmann tonometry in glaucoma patients
publishDate 2014
url http://scholarbank.nus.edu.sg/handle/10635/113597
_version_ 1821181749743321088