Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?

12th International Conference on Indoor Air Quality and Climate 2011

Saved in:
Bibliographic Details
Main Authors: Pantelic, J., Tham, K.W.
Other Authors: BUILDING
Format: Conference or Workshop Item
Published: 2014
Subjects:
Online Access:http://scholarbank.nus.edu.sg/handle/10635/114047
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: National University of Singapore
id sg-nus-scholar.10635-114047
record_format dspace
spelling sg-nus-scholar.10635-1140472015-01-23T11:18:38Z Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used? Pantelic, J. Tham, K.W. BUILDING Airborne infection disease spread Cough Thermal manikin Ventilation 12th International Conference on Indoor Air Quality and Climate 2011 3 2297-2302 2014-12-01T08:24:04Z 2014-12-01T08:24:04Z 2011 Conference Paper Pantelic, J.,Tham, K.W. (2011). Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?. 12th International Conference on Indoor Air Quality and Climate 2011 3 : 2297-2302. ScholarBank@NUS Repository. 9781627482721 http://scholarbank.nus.edu.sg/handle/10635/114047 NOT_IN_WOS Scopus
institution National University of Singapore
building NUS Library
country Singapore
collection ScholarBank@NUS
topic Airborne infection disease spread
Cough
Thermal manikin
Ventilation
spellingShingle Airborne infection disease spread
Cough
Thermal manikin
Ventilation
Pantelic, J.
Tham, K.W.
Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
description 12th International Conference on Indoor Air Quality and Climate 2011
author2 BUILDING
author_facet BUILDING
Pantelic, J.
Tham, K.W.
format Conference or Workshop Item
author Pantelic, J.
Tham, K.W.
author_sort Pantelic, J.
title Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
title_short Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
title_full Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
title_fullStr Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
title_full_unstemmed Can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
title_sort can increase of the supply flow rates cause reduction of the exposure to cough released droplets when total volume systems are used?
publishDate 2014
url http://scholarbank.nus.edu.sg/handle/10635/114047
_version_ 1681094767201484800