Load fatigue performance of a single-tooth implant abutment system: Effect of diameter
International Journal of Oral and Maxillofacial Implants
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2014
|
Subjects: | |
Online Access: | http://scholarbank.nus.edu.sg/handle/10635/79912 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | National University of Singapore |
id |
sg-nus-scholar.10635-79912 |
---|---|
record_format |
dspace |
spelling |
sg-nus-scholar.10635-799122024-11-10T02:34:27Z Load fatigue performance of a single-tooth implant abutment system: Effect of diameter Quek, C.E. Tan, K.B. Nicholls, J.I. RESTORATIVE DENTISTRY Implant diameter Implant failure Implant fracture Load fatigue Single-tooth replacement Torque International Journal of Oral and Maxillofacial Implants 21 6 929-936 2014-09-18T09:22:40Z 2014-09-18T09:22:40Z 2006-11 Article Quek, C.E.,Tan, K.B.,Nicholls, J.I. (2006-11). Load fatigue performance of a single-tooth implant abutment system: Effect of diameter. International Journal of Oral and Maxillofacial Implants 21 (6) : 929-936. ScholarBank@NUS Repository. 08822786 http://scholarbank.nus.edu.sg/handle/10635/79912 NOT_IN_WOS Scopus |
institution |
National University of Singapore |
building |
NUS Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NUS Library |
collection |
ScholarBank@NUS |
topic |
Implant diameter Implant failure Implant fracture Load fatigue Single-tooth replacement Torque |
spellingShingle |
Implant diameter Implant failure Implant fracture Load fatigue Single-tooth replacement Torque Quek, C.E. Tan, K.B. Nicholls, J.I. Load fatigue performance of a single-tooth implant abutment system: Effect of diameter |
description |
International Journal of Oral and Maxillofacial Implants |
author2 |
RESTORATIVE DENTISTRY |
author_facet |
RESTORATIVE DENTISTRY Quek, C.E. Tan, K.B. Nicholls, J.I. |
format |
Article |
author |
Quek, C.E. Tan, K.B. Nicholls, J.I. |
author_sort |
Quek, C.E. |
title |
Load fatigue performance of a single-tooth implant abutment system: Effect of diameter |
title_short |
Load fatigue performance of a single-tooth implant abutment system: Effect of diameter |
title_full |
Load fatigue performance of a single-tooth implant abutment system: Effect of diameter |
title_fullStr |
Load fatigue performance of a single-tooth implant abutment system: Effect of diameter |
title_full_unstemmed |
Load fatigue performance of a single-tooth implant abutment system: Effect of diameter |
title_sort |
load fatigue performance of a single-tooth implant abutment system: effect of diameter |
publishDate |
2014 |
url |
http://scholarbank.nus.edu.sg/handle/10635/79912 |
_version_ |
1821195651110666240 |