Placement and removal torque values of orthodontic miniscrew implants

Introduction: The purpose of this study was to analyze the maximum insertion torque (MIT) and maximum removal torque (MRT) values of orthodontic miniscrews. Methods: Two hundred eighty titanium miniscrews were placed in several sites in the maxillae and mandibles of orthodontic patients to provide s...

Full description

Saved in:
Bibliographic Details
Main Authors: Suzuki E.Y., Suzuki B.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-79955591942&partnerID=40&md5=28a71de41e029442d093dc2f76ff77e6
http://www.ncbi.nlm.nih.gov/pubmed/21536211
http://cmuir.cmu.ac.th/handle/6653943832/1048
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1048
record_format dspace
spelling th-cmuir.6653943832-10482014-08-29T09:17:40Z Placement and removal torque values of orthodontic miniscrew implants Suzuki E.Y. Suzuki B. Introduction: The purpose of this study was to analyze the maximum insertion torque (MIT) and maximum removal torque (MRT) values of orthodontic miniscrews. Methods: Two hundred eighty titanium miniscrews were placed in several sites in the maxillae and mandibles of orthodontic patients to provide skeletal anchorage. Two types of miniscrews were used: predrilling, cylindrical miniscrews, and self-drilling, conical miniscrews. A force of 50 g was applied with nickel-titanium coil springs 2 weeks after placement. MIT and MRT values were assessed with a digital torque gauge. Torque values were subjected to the paired t test, Student t test, chi-square test, and 1-way analysis of variance (ANOVA) (P <0.05). Results: MIT values were significantly higher for the self-drilling miniscrews (mean, 14.5 Ncm; 95% CI, 13.6-15.3) than for the predrilling miniscrews (mean, 9.2 Ncm; 95% CI, 8.6-9.9) in all implant sites. For both predrilling and self-drilling miniscrews, the highest MIT values were observed at the midpalatal suture site followed by the dentoalveolar bones of the mandible and maxilla, respectively. In contrast, MRT values were significantly higher for the predrilling miniscrews (mean, 22.6 Ncm; 95% CI, 22.0-23.3) than for the self-drilling miniscrews (mean, 17.6 Ncm; 95% CI, 16.8-18.4). Accordingly, the mean torque ratio of predrilling miniscrews was twice that of the self-drilling miniscrews. Conclusions: An inverse relationship between MIT and MRT values was observed. The results suggest that relatively lower MIT values were more favorable to osseointegration than higher values. Copyright © 2011 by the American Association of Orthodontists. 2014-08-29T09:17:40Z 2014-08-29T09:17:40Z 2011 Article 8895406 10.1016/j.ajodo.2010.11.017 21536211 AJOOE http://www.scopus.com/inward/record.url?eid=2-s2.0-79955591942&partnerID=40&md5=28a71de41e029442d093dc2f76ff77e6 http://www.ncbi.nlm.nih.gov/pubmed/21536211 http://cmuir.cmu.ac.th/handle/6653943832/1048 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description Introduction: The purpose of this study was to analyze the maximum insertion torque (MIT) and maximum removal torque (MRT) values of orthodontic miniscrews. Methods: Two hundred eighty titanium miniscrews were placed in several sites in the maxillae and mandibles of orthodontic patients to provide skeletal anchorage. Two types of miniscrews were used: predrilling, cylindrical miniscrews, and self-drilling, conical miniscrews. A force of 50 g was applied with nickel-titanium coil springs 2 weeks after placement. MIT and MRT values were assessed with a digital torque gauge. Torque values were subjected to the paired t test, Student t test, chi-square test, and 1-way analysis of variance (ANOVA) (P <0.05). Results: MIT values were significantly higher for the self-drilling miniscrews (mean, 14.5 Ncm; 95% CI, 13.6-15.3) than for the predrilling miniscrews (mean, 9.2 Ncm; 95% CI, 8.6-9.9) in all implant sites. For both predrilling and self-drilling miniscrews, the highest MIT values were observed at the midpalatal suture site followed by the dentoalveolar bones of the mandible and maxilla, respectively. In contrast, MRT values were significantly higher for the predrilling miniscrews (mean, 22.6 Ncm; 95% CI, 22.0-23.3) than for the self-drilling miniscrews (mean, 17.6 Ncm; 95% CI, 16.8-18.4). Accordingly, the mean torque ratio of predrilling miniscrews was twice that of the self-drilling miniscrews. Conclusions: An inverse relationship between MIT and MRT values was observed. The results suggest that relatively lower MIT values were more favorable to osseointegration than higher values. Copyright © 2011 by the American Association of Orthodontists.
format Article
author Suzuki E.Y.
Suzuki B.
spellingShingle Suzuki E.Y.
Suzuki B.
Placement and removal torque values of orthodontic miniscrew implants
author_facet Suzuki E.Y.
Suzuki B.
author_sort Suzuki E.Y.
title Placement and removal torque values of orthodontic miniscrew implants
title_short Placement and removal torque values of orthodontic miniscrew implants
title_full Placement and removal torque values of orthodontic miniscrew implants
title_fullStr Placement and removal torque values of orthodontic miniscrew implants
title_full_unstemmed Placement and removal torque values of orthodontic miniscrew implants
title_sort placement and removal torque values of orthodontic miniscrew implants
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-79955591942&partnerID=40&md5=28a71de41e029442d093dc2f76ff77e6
http://www.ncbi.nlm.nih.gov/pubmed/21536211
http://cmuir.cmu.ac.th/handle/6653943832/1048
_version_ 1681419583594954752