Analysis of single pole reclosing on EHV line in Thailand

This paper presents an investigation of single pole reclosing on EHV transmission lines in Thailand. The reactor compensation of single pole switching on both single and double circuit lines is reviewed. The existing EHV line is simulated. At the boundary of the simulation, the external grid was rep...

Full description

Saved in:
Bibliographic Details
Main Authors: Ngamsanroaj K., Premrudeepreechacharn S.
Format: Conference or Workshop Item
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-48349129494&partnerID=40&md5=90e43da6b1241ae0ccb2a9b9edd1ddfb
http://cmuir.cmu.ac.th/handle/6653943832/1316
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1316
record_format dspace
spelling th-cmuir.6653943832-13162014-08-29T09:29:08Z Analysis of single pole reclosing on EHV line in Thailand Ngamsanroaj K. Premrudeepreechacharn S. This paper presents an investigation of single pole reclosing on EHV transmission lines in Thailand. The reactor compensation of single pole switching on both single and double circuit lines is reviewed. The existing EHV line is simulated. At the boundary of the simulation, the external grid was represented by positive/zero sequence equivalent impedances. All simulations were done with EMTP. Methods of reducing this secondary current are considered in this paper. © 2007 IEEE. 2014-08-29T09:29:08Z 2014-08-29T09:29:08Z 2007 Conference Paper 9781424415830 10.1109/LESCPE.2007.4437380 72865 http://www.scopus.com/inward/record.url?eid=2-s2.0-48349129494&partnerID=40&md5=90e43da6b1241ae0ccb2a9b9edd1ddfb http://cmuir.cmu.ac.th/handle/6653943832/1316 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description This paper presents an investigation of single pole reclosing on EHV transmission lines in Thailand. The reactor compensation of single pole switching on both single and double circuit lines is reviewed. The existing EHV line is simulated. At the boundary of the simulation, the external grid was represented by positive/zero sequence equivalent impedances. All simulations were done with EMTP. Methods of reducing this secondary current are considered in this paper. © 2007 IEEE.
format Conference or Workshop Item
author Ngamsanroaj K.
Premrudeepreechacharn S.
spellingShingle Ngamsanroaj K.
Premrudeepreechacharn S.
Analysis of single pole reclosing on EHV line in Thailand
author_facet Ngamsanroaj K.
Premrudeepreechacharn S.
author_sort Ngamsanroaj K.
title Analysis of single pole reclosing on EHV line in Thailand
title_short Analysis of single pole reclosing on EHV line in Thailand
title_full Analysis of single pole reclosing on EHV line in Thailand
title_fullStr Analysis of single pole reclosing on EHV line in Thailand
title_full_unstemmed Analysis of single pole reclosing on EHV line in Thailand
title_sort analysis of single pole reclosing on ehv line in thailand
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-48349129494&partnerID=40&md5=90e43da6b1241ae0ccb2a9b9edd1ddfb
http://cmuir.cmu.ac.th/handle/6653943832/1316
_version_ 1681419647827574784