Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant

The aim of this paper is to simulate the performance of an air source heat pump water heater using carbon dioxide (CO2) as a working fluid. The heat pump water heating system consists of a compressor, a gas cooler, an expansion device and an evaporator. The computer simulation model has been develop...

全面介紹

Saved in:
書目詳細資料
Main Authors: Laipradit P., Tiansuwan J., Kiatsiriroat T., Aye L.
格式: Article
語言:English
出版: 2014
在線閱讀:http://www.scopus.com/inward/record.url?eid=2-s2.0-40749146001&partnerID=40&md5=20ebafbbc86d34348c5c205a13e939cc
http://cmuir.cmu.ac.th/handle/6653943832/1402
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Chiang Mai University
語言: English
id th-cmuir.6653943832-1402
record_format dspace
spelling th-cmuir.6653943832-14022014-08-29T09:29:15Z Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant Laipradit P. Tiansuwan J. Kiatsiriroat T. Aye L. The aim of this paper is to simulate the performance of an air source heat pump water heater using carbon dioxide (CO2) as a working fluid. The heat pump water heating system consists of a compressor, a gas cooler, an expansion device and an evaporator. The computer simulation model has been developed by using the heat transfer data and the thermodynamic properties Of CO2. The effects on the heat pump performance by the operating parameters such as the compressor rotational speed, the inlet water temperature at the gas cooler, the inlet air temperature at the evaporator and the mass flow rate ratio of water to refrigerant were presented. For rated capacities of a 4 kW compressor with a 10 kW gas cooler and a 6 kW evaporator, the coefficient of performance is found to be between 2.0 and 3.0. The mass flow rate ratio of water and CO2 between 1.2 and 2.2 is the most suitable value for generating hot water temperature above 60°C at 15-25°C ambient air temperature. Copyright © 2007 John Wiley & Sons, Ltd. 2014-08-29T09:29:15Z 2014-08-29T09:29:15Z 2008 Article 0363907X 10.1002/er.1357 IJERD http://www.scopus.com/inward/record.url?eid=2-s2.0-40749146001&partnerID=40&md5=20ebafbbc86d34348c5c205a13e939cc http://cmuir.cmu.ac.th/handle/6653943832/1402 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description The aim of this paper is to simulate the performance of an air source heat pump water heater using carbon dioxide (CO2) as a working fluid. The heat pump water heating system consists of a compressor, a gas cooler, an expansion device and an evaporator. The computer simulation model has been developed by using the heat transfer data and the thermodynamic properties Of CO2. The effects on the heat pump performance by the operating parameters such as the compressor rotational speed, the inlet water temperature at the gas cooler, the inlet air temperature at the evaporator and the mass flow rate ratio of water to refrigerant were presented. For rated capacities of a 4 kW compressor with a 10 kW gas cooler and a 6 kW evaporator, the coefficient of performance is found to be between 2.0 and 3.0. The mass flow rate ratio of water and CO2 between 1.2 and 2.2 is the most suitable value for generating hot water temperature above 60°C at 15-25°C ambient air temperature. Copyright © 2007 John Wiley & Sons, Ltd.
format Article
author Laipradit P.
Tiansuwan J.
Kiatsiriroat T.
Aye L.
spellingShingle Laipradit P.
Tiansuwan J.
Kiatsiriroat T.
Aye L.
Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
author_facet Laipradit P.
Tiansuwan J.
Kiatsiriroat T.
Aye L.
author_sort Laipradit P.
title Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
title_short Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
title_full Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
title_fullStr Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
title_full_unstemmed Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
title_sort theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-40749146001&partnerID=40&md5=20ebafbbc86d34348c5c205a13e939cc
http://cmuir.cmu.ac.th/handle/6653943832/1402
_version_ 1681419663836184576