Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode

The mathematical model of a closed-end pulsating heat pipe (CEPHP) with a bottom heat mode at different inclination angles was constructed. The closed-end pulsating heat pipe was modeled with specified assumptions that were observed visually (i.e., the scaling factor for geometrical size and the fre...

Full description

Saved in:
Bibliographic Details
Main Authors: Sakulchangsatjatai P., Chareonsawan P., Waowaew T., Terdtoon P., Murakami M.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-38749146305&partnerID=40&md5=09443512d35e9fed723945cbda1ee172
http://cmuir.cmu.ac.th/handle/6653943832/1404
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1404
record_format dspace
spelling th-cmuir.6653943832-14042014-08-29T09:29:15Z Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode Sakulchangsatjatai P. Chareonsawan P. Waowaew T. Terdtoon P. Murakami M. The mathematical model of a closed-end pulsating heat pipe (CEPHP) with a bottom heat mode at different inclination angles was constructed. The closed-end pulsating heat pipe was modeled with specified assumptions that were observed visually (i.e., the scaling factor for geometrical size and the frequency of bubble generation inside the liquid slugs). The solution for all of the basic governing equations of liquid film, liquid slugs, and vapor plugs, in which the effects of surface tension, viscous friction of the working fluid, and perfect gas were included, has been numerically obtained by solving a series of ordinary differential equations by means of the explicit method. However, the solution for the momentum equation of liquid slugs was numerically obtained by solving a series of partial differential equations by using the implicit method. Results from the model clearly simulated the dynamics of the internal working fluid in the CEPHP. Moreover, the results were compared with existing experimental data, and good agreement was found with an error range of 13%. It was also noted that the maximum heat transfer rate of the CEPHP with bottom heat mode occurred at the highest evaporator temperature (150C for this study) and inclination angles of 70-80 degrees from horizontal axis. The boiling frequencies in this range of inclination angles were observed by visual experiment and seen to be at their highest values. This has been justified by the higher amount of liquid in the evaporator section as well as the change in flow pattern to a stratified flow (inclination tube). 2014-08-29T09:29:15Z 2014-08-29T09:29:15Z 2008 Article 01457632 10.1080/01457630701756173 HTEND http://www.scopus.com/inward/record.url?eid=2-s2.0-38749146305&partnerID=40&md5=09443512d35e9fed723945cbda1ee172 http://cmuir.cmu.ac.th/handle/6653943832/1404 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description The mathematical model of a closed-end pulsating heat pipe (CEPHP) with a bottom heat mode at different inclination angles was constructed. The closed-end pulsating heat pipe was modeled with specified assumptions that were observed visually (i.e., the scaling factor for geometrical size and the frequency of bubble generation inside the liquid slugs). The solution for all of the basic governing equations of liquid film, liquid slugs, and vapor plugs, in which the effects of surface tension, viscous friction of the working fluid, and perfect gas were included, has been numerically obtained by solving a series of ordinary differential equations by means of the explicit method. However, the solution for the momentum equation of liquid slugs was numerically obtained by solving a series of partial differential equations by using the implicit method. Results from the model clearly simulated the dynamics of the internal working fluid in the CEPHP. Moreover, the results were compared with existing experimental data, and good agreement was found with an error range of 13%. It was also noted that the maximum heat transfer rate of the CEPHP with bottom heat mode occurred at the highest evaporator temperature (150C for this study) and inclination angles of 70-80 degrees from horizontal axis. The boiling frequencies in this range of inclination angles were observed by visual experiment and seen to be at their highest values. This has been justified by the higher amount of liquid in the evaporator section as well as the change in flow pattern to a stratified flow (inclination tube).
format Article
author Sakulchangsatjatai P.
Chareonsawan P.
Waowaew T.
Terdtoon P.
Murakami M.
spellingShingle Sakulchangsatjatai P.
Chareonsawan P.
Waowaew T.
Terdtoon P.
Murakami M.
Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode
author_facet Sakulchangsatjatai P.
Chareonsawan P.
Waowaew T.
Terdtoon P.
Murakami M.
author_sort Sakulchangsatjatai P.
title Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode
title_short Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode
title_full Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode
title_fullStr Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode
title_full_unstemmed Mathematical modeling of closed-End pulsating heat pipes pperating with a bottom heat mode
title_sort mathematical modeling of closed-end pulsating heat pipes pperating with a bottom heat mode
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-38749146305&partnerID=40&md5=09443512d35e9fed723945cbda1ee172
http://cmuir.cmu.ac.th/handle/6653943832/1404
_version_ 1681419664208429056