Analysis of a heat pump with solid desiccant tube bank
In this paper, the analysis of silica gel formed in a staggered tube bank arrangement for the reduction of energy consumption in a heat pump dehumidifier is presented. The mathematical models for the desiccant and the heat pump have been developed. The simulated results agree quite well with those o...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-0036572149&partnerID=40&md5=5a54aa6cb1c956e65cf6872511544ddc http://cmuir.cmu.ac.th/handle/6653943832/1411 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-1411 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-14112014-08-29T09:29:16Z Analysis of a heat pump with solid desiccant tube bank Kiatsiriroat T. Tachajapong W. In this paper, the analysis of silica gel formed in a staggered tube bank arrangement for the reduction of energy consumption in a heat pump dehumidifier is presented. The mathematical models for the desiccant and the heat pump have been developed. The simulated results agree quite well with those of the experiments. The desiccant could reduce the heat pump load by about 7-20 per cent at the inlet air conditions of about 30-50°C and 70-90 per cent RH. Copyright © 2002 John Wiley & Sons, Ltd. 2014-08-29T09:29:16Z 2014-08-29T09:29:16Z 2002 Article 0363907X 10.1002/er.801 IJERD http://www.scopus.com/inward/record.url?eid=2-s2.0-0036572149&partnerID=40&md5=5a54aa6cb1c956e65cf6872511544ddc http://cmuir.cmu.ac.th/handle/6653943832/1411 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
In this paper, the analysis of silica gel formed in a staggered tube bank arrangement for the reduction of energy consumption in a heat pump dehumidifier is presented. The mathematical models for the desiccant and the heat pump have been developed. The simulated results agree quite well with those of the experiments. The desiccant could reduce the heat pump load by about 7-20 per cent at the inlet air conditions of about 30-50°C and 70-90 per cent RH. Copyright © 2002 John Wiley & Sons, Ltd. |
format |
Article |
author |
Kiatsiriroat T. Tachajapong W. |
spellingShingle |
Kiatsiriroat T. Tachajapong W. Analysis of a heat pump with solid desiccant tube bank |
author_facet |
Kiatsiriroat T. Tachajapong W. |
author_sort |
Kiatsiriroat T. |
title |
Analysis of a heat pump with solid desiccant tube bank |
title_short |
Analysis of a heat pump with solid desiccant tube bank |
title_full |
Analysis of a heat pump with solid desiccant tube bank |
title_fullStr |
Analysis of a heat pump with solid desiccant tube bank |
title_full_unstemmed |
Analysis of a heat pump with solid desiccant tube bank |
title_sort |
analysis of a heat pump with solid desiccant tube bank |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-0036572149&partnerID=40&md5=5a54aa6cb1c956e65cf6872511544ddc http://cmuir.cmu.ac.th/handle/6653943832/1411 |
_version_ |
1681419665540120576 |