Analysis of a heat pump with solid desiccant tube bank

In this paper, the analysis of silica gel formed in a staggered tube bank arrangement for the reduction of energy consumption in a heat pump dehumidifier is presented. The mathematical models for the desiccant and the heat pump have been developed. The simulated results agree quite well with those o...

Full description

Saved in:
Bibliographic Details
Main Authors: Kiatsiriroat T., Tachajapong W.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-0036572149&partnerID=40&md5=5a54aa6cb1c956e65cf6872511544ddc
http://cmuir.cmu.ac.th/handle/6653943832/1411
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1411
record_format dspace
spelling th-cmuir.6653943832-14112014-08-29T09:29:16Z Analysis of a heat pump with solid desiccant tube bank Kiatsiriroat T. Tachajapong W. In this paper, the analysis of silica gel formed in a staggered tube bank arrangement for the reduction of energy consumption in a heat pump dehumidifier is presented. The mathematical models for the desiccant and the heat pump have been developed. The simulated results agree quite well with those of the experiments. The desiccant could reduce the heat pump load by about 7-20 per cent at the inlet air conditions of about 30-50°C and 70-90 per cent RH. Copyright © 2002 John Wiley & Sons, Ltd. 2014-08-29T09:29:16Z 2014-08-29T09:29:16Z 2002 Article 0363907X 10.1002/er.801 IJERD http://www.scopus.com/inward/record.url?eid=2-s2.0-0036572149&partnerID=40&md5=5a54aa6cb1c956e65cf6872511544ddc http://cmuir.cmu.ac.th/handle/6653943832/1411 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description In this paper, the analysis of silica gel formed in a staggered tube bank arrangement for the reduction of energy consumption in a heat pump dehumidifier is presented. The mathematical models for the desiccant and the heat pump have been developed. The simulated results agree quite well with those of the experiments. The desiccant could reduce the heat pump load by about 7-20 per cent at the inlet air conditions of about 30-50°C and 70-90 per cent RH. Copyright © 2002 John Wiley & Sons, Ltd.
format Article
author Kiatsiriroat T.
Tachajapong W.
spellingShingle Kiatsiriroat T.
Tachajapong W.
Analysis of a heat pump with solid desiccant tube bank
author_facet Kiatsiriroat T.
Tachajapong W.
author_sort Kiatsiriroat T.
title Analysis of a heat pump with solid desiccant tube bank
title_short Analysis of a heat pump with solid desiccant tube bank
title_full Analysis of a heat pump with solid desiccant tube bank
title_fullStr Analysis of a heat pump with solid desiccant tube bank
title_full_unstemmed Analysis of a heat pump with solid desiccant tube bank
title_sort analysis of a heat pump with solid desiccant tube bank
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-0036572149&partnerID=40&md5=5a54aa6cb1c956e65cf6872511544ddc
http://cmuir.cmu.ac.th/handle/6653943832/1411
_version_ 1681419665540120576