Harmonic resonance assessment in low voltage distribution system

In a power system, due to proliferation of power electronic equipments that produce harmonic current, harmonic resonance can occur when the system natural frequency closes or corresponds to the frequency of harmonic current source. This paper presents a power system simulation of medium/low voltage...

Full description

Saved in:
Bibliographic Details
Main Authors: Pongsriwat C., SPremrudeepreechacharn
Format: Conference or Workshop Item
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-20444483336&partnerID=40&md5=87c08bb9378004d58c973933b3464859
http://cmuir.cmu.ac.th/handle/6653943832/1516
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1516
record_format dspace
spelling th-cmuir.6653943832-15162014-08-29T09:29:25Z Harmonic resonance assessment in low voltage distribution system Pongsriwat C. SPremrudeepreechacharn In a power system, due to proliferation of power electronic equipments that produce harmonic current, harmonic resonance can occur when the system natural frequency closes or corresponds to the frequency of harmonic current source. This paper presents a power system simulation of medium/low voltage system which contains 22 kV/400 V transformer, harmonic load (6 pulse converter), and low voltage fixed capacitor. By using DIgSILENT PowerFactory Program, the harmonic component of capacitor current, system response and harmonic impedance are presented. Assessment of harmonic resonance effect on low voltage capacitor are considered with IEEE Std. 1036-1992 Guide for Application of Shunt Power Capacitor which provides limitations of capacitor on voltage, current and reactive power for determination of the maximum allowable harmonic levels. Moreover, the assessment of harmonic distortions are also compared with IEEE Std. 519-1992. © 2004 IEEE. 2014-08-29T09:29:25Z 2014-08-29T09:29:25Z 2004 Conference Paper 0780386108 65033 http://www.scopus.com/inward/record.url?eid=2-s2.0-20444483336&partnerID=40&md5=87c08bb9378004d58c973933b3464859 http://cmuir.cmu.ac.th/handle/6653943832/1516 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description In a power system, due to proliferation of power electronic equipments that produce harmonic current, harmonic resonance can occur when the system natural frequency closes or corresponds to the frequency of harmonic current source. This paper presents a power system simulation of medium/low voltage system which contains 22 kV/400 V transformer, harmonic load (6 pulse converter), and low voltage fixed capacitor. By using DIgSILENT PowerFactory Program, the harmonic component of capacitor current, system response and harmonic impedance are presented. Assessment of harmonic resonance effect on low voltage capacitor are considered with IEEE Std. 1036-1992 Guide for Application of Shunt Power Capacitor which provides limitations of capacitor on voltage, current and reactive power for determination of the maximum allowable harmonic levels. Moreover, the assessment of harmonic distortions are also compared with IEEE Std. 519-1992. © 2004 IEEE.
format Conference or Workshop Item
author Pongsriwat C.
SPremrudeepreechacharn
spellingShingle Pongsriwat C.
SPremrudeepreechacharn
Harmonic resonance assessment in low voltage distribution system
author_facet Pongsriwat C.
SPremrudeepreechacharn
author_sort Pongsriwat C.
title Harmonic resonance assessment in low voltage distribution system
title_short Harmonic resonance assessment in low voltage distribution system
title_full Harmonic resonance assessment in low voltage distribution system
title_fullStr Harmonic resonance assessment in low voltage distribution system
title_full_unstemmed Harmonic resonance assessment in low voltage distribution system
title_sort harmonic resonance assessment in low voltage distribution system
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-20444483336&partnerID=40&md5=87c08bb9378004d58c973933b3464859
http://cmuir.cmu.ac.th/handle/6653943832/1516
_version_ 1681419685090820096