Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experienc...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-84866760688&partnerID=40&md5=6786cd88d83ac3d8198fca766f33100f http://cmuir.cmu.ac.th/handle/6653943832/1602 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-1602 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-16022014-08-29T09:29:30Z Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV Thipprasert W. Jirapong P. Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm 2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm 2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE. 2014-08-29T09:29:30Z 2014-08-29T09:29:30Z 2012 Conference Paper 9.78147E+12 10.1109/ECTICon.2012.6254199 92855 http://www.scopus.com/inward/record.url?eid=2-s2.0-84866760688&partnerID=40&md5=6786cd88d83ac3d8198fca766f33100f http://cmuir.cmu.ac.th/handle/6653943832/1602 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm 2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm 2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE. |
format |
Conference or Workshop Item |
author |
Thipprasert W. Jirapong P. |
spellingShingle |
Thipprasert W. Jirapong P. Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
author_facet |
Thipprasert W. Jirapong P. |
author_sort |
Thipprasert W. |
title |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_short |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_full |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_fullStr |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_full_unstemmed |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_sort |
comparison of ac flashover performance for line post and pin post insulators in distribution 22 kv |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-84866760688&partnerID=40&md5=6786cd88d83ac3d8198fca766f33100f http://cmuir.cmu.ac.th/handle/6653943832/1602 |
_version_ |
1681419701108867072 |