Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV

Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consist of pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that...

Full description

Saved in:
Bibliographic Details
Main Authors: Wimonthanasit P., Chaidee E., Jirapong P., Thipprasert W.
Format: Conference or Workshop Item
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-84872696259&partnerID=40&md5=46aa976441fc9c87ce73647169a976ad
http://cmuir.cmu.ac.th/handle/6653943832/1615
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1615
record_format dspace
spelling th-cmuir.6653943832-16152014-08-29T09:29:31Z Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV Wimonthanasit P. Chaidee E. Jirapong P. Thipprasert W. Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consist of pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from the artificial pollution tests according to IEC 60507 in the chamber for tests with standard porcelain insulators consist, pin post, line post and pin type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of pin type insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of pin type insulator increased to 11.4 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post and pin type insulators in the serious pollution area. This data will be useful to be guideline for solving problems and reducing power loss from leakage current on the surface of the insulators as a result of surface dirt and pollution. Moreover, it will be useful to select or design suitable insulators for using in places with salt conditions, high rainfall, high wind speeds and high humidity. © (2013) Trans Tech Publications, Switzerland. 2014-08-29T09:29:31Z 2014-08-29T09:29:31Z 2013 Conference Paper 9783037855638 10226680 10.4028/www.scientific.net/AMR.622-623.1901 95057 http://www.scopus.com/inward/record.url?eid=2-s2.0-84872696259&partnerID=40&md5=46aa976441fc9c87ce73647169a976ad http://cmuir.cmu.ac.th/handle/6653943832/1615 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consist of pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from the artificial pollution tests according to IEC 60507 in the chamber for tests with standard porcelain insulators consist, pin post, line post and pin type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of pin type insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of pin type insulator increased to 11.4 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post and pin type insulators in the serious pollution area. This data will be useful to be guideline for solving problems and reducing power loss from leakage current on the surface of the insulators as a result of surface dirt and pollution. Moreover, it will be useful to select or design suitable insulators for using in places with salt conditions, high rainfall, high wind speeds and high humidity. © (2013) Trans Tech Publications, Switzerland.
format Conference or Workshop Item
author Wimonthanasit P.
Chaidee E.
Jirapong P.
Thipprasert W.
spellingShingle Wimonthanasit P.
Chaidee E.
Jirapong P.
Thipprasert W.
Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV
author_facet Wimonthanasit P.
Chaidee E.
Jirapong P.
Thipprasert W.
author_sort Wimonthanasit P.
title Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV
title_short Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV
title_full Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV
title_fullStr Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV
title_full_unstemmed Analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kV
title_sort analysis and comparison of pollution flashover performance of porcelain insulators in distribution system 22 kv
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-84872696259&partnerID=40&md5=46aa976441fc9c87ce73647169a976ad
http://cmuir.cmu.ac.th/handle/6653943832/1615
_version_ 1681419703511154688